Morphological predictors of restenosis after coronary stenting in humans.
نویسندگان
چکیده
BACKGROUND Experimental studies suggest that arterial injury and inflammation lead to increased neointimal growth after stenting. Despite the increased use of coronary stents in humans, there are only limited pathological data on the morphological features of in-stent restenosis. METHODS AND RESULTS Detailed histology was performed on 116 stents, implanted > or =90 days in 87 coronary arteries, from 56 patients (mean age, 59+/-13 years). The mean duration of stent implant was 10 months. In-stent restenosis was defined as a stent area stenosis of >75%. Lumen area increased as stent area increased (r2=0.27, P=0.0001), but there was a much stronger correlation between stent area and neointimal area (r2=0.70, P<0.0001). Arterial medial fracture was associated with a 29% increase (P<0.01) in neointimal thickness compared with arteries with an intact media. Neointimal thickness (P=0.0001), inflammatory cell density (P<0.0001), and neointimal vascular channel density (P<0.0001) were greater when struts were in contact with a ruptured arterial media compared with fibrous plaque or an intact fibrous cap. Stent strut penetration into a lipid core was associated with increased neointimal thickness (P=0.04) and inflammatory cell density (P=0.03). Neointimal inflammatory cell content was 2.4-fold greater in stents with restenosis versus no restenosis, and inflammation was associated with increased neoangiogenesis. CONCLUSIONS Coronary stenting that is accompanied by medial damage or penetration of the stent into a lipid core induces increased arterial inflammation, which is associated with increased neointimal growth. These data suggest the use of stenting strategies that reduce inflammation and neoangiogenesis to reduce the incidence of restenosis.
منابع مشابه
Independent predictors of restenosis after percutaneous coronary revascularization in haemodialysis patients.
BACKGROUND Percutaneous balloon angioplasty has become a well-established and routine procedure for coronary revascularization of haemodialysis patients with coronary artery disease. However, the incidence of restenosis after balloon angioplasty is significantly higher in haemodialysis patients than in the general population. We performed a retrospective study comparing balloon angioplasty with...
متن کاملOverview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent
Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...
متن کاملPredictors of restenosis after coronary stent implantation.
OBJECTIVES We sought to determine predictors of restenosis after coronary stenting (CS) in a consecutive series of patients. BACKGROUND Although stenting in highly selected patient groups reduces restenosis, the results of stenting in a heterogeneous patient group and the effects of clinical and procedural factors on stent restenosis are currently unclear. METHODS We analyzed the 6-month an...
متن کاملPeriprocedural soluble P- and E-selectin levels fail as predictors of clinical restenosis in patients treated with elective coronary stenting.
An increasing amount of basic scientific data indicates that adhesion molecules may be involved in the pathogenesis of vessel re-narrowing in patients undergoing coronary angioplasty. Furthermore, inflammation is suggested to be a pivotal mechanism linking atherosclerosis and restenosis. The aim of this study was to assess if periprocedural evaluation of soluble P-selectin (sP-selectin) and E-s...
متن کاملNeointimal tissue response at sites of coronary stenting in humans: macroscopic, histological, and immunohistochemical analyses.
BACKGROUND Experimental animal studies have shown that coronary stenting induces neointimal proliferation. However, the histopathological events after coronary stenting in humans have not been studied systematically. METHODS AND RESULTS We investigated 11 stented coronary arteries (9 Palmaz-Schatz stents, 1 Wiktor stent, and 1 ACS Multi-Link stent) obtained from 11 patients who had died 2 day...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 105 25 شماره
صفحات -
تاریخ انتشار 2002