Lubrication Analysis of Rotary Compressors for HFC Refrigerants

نویسندگان

  • K. Minami
  • H. Hattori
  • M. Hayano
  • Katsuya Minami
  • Hitoshi Hattori
  • Makoto Hayano
چکیده

In this study, a practical numerical analysis has been developed in order to investigate the lubrication characteristics between a rolling piston and a crank of rotary compressors. This analysis is treated as a coupled problem of the momentum equations and the Reynolds equation of oil film. Using this analysis, the lubrication characteristics between the rolling piston and the crank for 2-cylinder rotary compressors were evaluated for R22 and R410A. Furthermore, the lubrication characteristics on the journal bearings were also analyzed using the already developed tool [ 1]. Measured pressure and oil viscosity in a inverter driven heat pump system were used as the analysis conditions. The oil film thickness and the motions of the rolling piston and the motor rotor were obtained as the analysis results. It made clear that the lubrication characteristics of the rolling piston and the journal bearings with R41 OA refrigerant is better than those with R22. INTRODUCTION R410A (R32/125, 50/50wt%) is an alternative refrigerant ofR22 for air-conditioners, and its capacities have been evaluated widely. Mineral oil is applicable to R22 system as lubricant, but it cannot be used in R410A system because of poor miscibility with R410A. Therefore, polyolester oil which is miscible with R41 OA is mainly used as alternative oil. The cooling capacity of R41 OA derived from the refrigerant property is about 1.4 times as much as that of R22[2]. So, the discharge volume of compressors for R41 OA is required to redesign to adjust the cooling capacity. It is important to investigate lubrication characteristics of compressors with R410A in order to develop the optimum lubricant and to design compressors for R410A. Therefore, many durability tests and numerical analysis were carried out to evaluate the lubrication characteristics with R 41 OA. In the present study, we developed the practical program for lubrication analysis between the rolling piston and the crank of rotary compressors. The selection of lubricating oil and the optimum design of rotary compressors were done by using this analysis and another analysis for journal bearings in addition to the experimental results of the compressor durability tests and oil lubricity evaluations [3]. In this paper, at first, the governing equations and the procedure of the analysis are described. As an example of the analysis results, the optimum lubrication characteristics between the rolling piston and the crank and on the journal bearings of the 2-cylinder rotary compressor for R 41 OA are shown by relatively comparing with the analysis results for R22. GOVERNING EQUATIONS Fig.l shows the schematic drawing of the compression part in a rotary compressor, and Fig.2 shows the schematic drawing of rolling-piston/crank and its coordinate system for the analysis. The rolling piston is loaded large dynamic forces such as unbalanced forces, gas forces and vane forces. Therefore, the Reynolds equations are used to calculate the reaction force of oil film.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assuring Reliability of Compressors Using HFC Refrigerants

In Japan, the refrigerant used in room air-conditioners has been changed from HCFC-22 (R-22) to R-410A, a blend of HFC-32 and HFC-125 (50/50 vt%), in order to protect the ozone layer. Generally, the miscibility between the refrigerant and refrigeration oil must be assured, because the oil needs to return to the compressor from the refrigeration cycle and lubricate the sliding parts. Alternative...

متن کامل

Simulation and Validation of a R404A/CO2 Cascade Refrigeration System

The interest in natural refrigerants, such as carbon dioxide, has been growing in recent years due to the high direct global warming potential of common HFC refrigerants. Despite the environment-friendly characteristics of CO2 as a refrigerant, due to high heat rejection temperatures and transcritical operation, CO2 cannot match the high energy efficiency associated with current HFC technology....

متن کامل

High Efficiency Compact Rotary Compressor Using the New Refrigerant HFC-134a for Automotive Air Conditioners

In accordance with worldwide consensus, the use of chlorofluorocarbons, which play an important role in damaging the ozone layer, should be completely abolished by the end of 1995. This provided the impetus for developing the three vane rotary compressor. Formerly CFC-12 was used as the refrigerant in automotive air conditioners, until HFC-134a was substituted for CFC-12. In response to the cha...

متن کامل

Artificial Neural Network Involved in the Action of Optimum Mixed Refrigerant (Domestic Refrigerator) (TECHNICAL NOTE)

This analysis principally focuses on the implementation of Radial basis function (RBF) and back propagation (BPA) algorithms for training artificial neural network (ANN) to get the optimum mixture of Hydro fluorocarbon (HFC) and organic compound (Hydrocarbons) for obtaining higher coefficient of Performances (COPs). The thermodynamical properties of mixed refrigerants are observed using REFPROP...

متن کامل

A Study on Lubricity of Polyolester for Alternative Refrigerant HFC- 134a

This paper presents the experimental research into the evaluation of lubricity for polyolester (POE) lubricant with HFC-134a refrigerant in rotary and reciprocating compressors for household refrigerators. In order to evaluate the lubricity for POE lubricant with HFC-134a refrigerant, we conducted 4-balls wear tests in the mixing environment of POE lubricant and HFC-134a refrigerant. In the pre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014