Stabilization and frequency measurement of the I2-stabilized Nd: YAG laser
نویسندگان
چکیده
We report improved stabilization results for and progress toward a more accurate frequency measurement of the 532 nm iodine-stabilized system based on a frequency-doubled Nd : YAG ring laser. We confirm the CCL-adopted frequency well within its stated uncertainty ( 40 kHz).
منابع مشابه
Portable I2-stabilized Nd: YAG laser for international comparisons
We have established a compact and transportable I2-stabilized Nd:YAG laser for international comparisons of laser frequency. The root Allan variance of the portable laser has reached 3 9 10 14 when the integration time is longer than 200 s. The results of an international comparison between the National Research Laboratory of Metrology (NRLM), Tsukuba, Japan and the JILA (formerly the Joint Ins...
متن کاملProgress toward absolute frequency measurements of the 127 I2-stabilized Nd: YAG laser at 563.2 THz/532 nm
Progress on the development of a frequency chain devoted to the absolute frequency measurement of 127I2-stabilized lasers around 563.2 THz/532 nm is reported. The aim of this work is the improvement of the accuracy—by at least one order of magnitude—of the absolute frequency of this standard. The scheme is based on the frequency combination of two wellknown optical frequency standards, namely a...
متن کاملCryotherapy is more effective and faster than Q-switched Nd-YAG laser fordepigmentation in universal vitiligo patients
Background: Although cryotherapy has been reported as atechnique for depigmenting residual pigmented patches inpatients with universal vitiligo, Q-switched Nd-YAG lasershave not yet been used for this purpose. The aim of this studywas to compare the efficacy of cryotherapy with that of 532nmQ-switched Nd-YAG laser therapy for depigmentation in patientswith universal vitiligo.Method: Six adult p...
متن کاملInfluence of shielding gas composition on weld structure in pulsed Nd: YAG laser welding
This work studied the effect of additions of carbon dioxide to argon shielding gas on the weld shape and microstructure of ST14 steel in pulsed Nd: YAG laser welding. By additions of carbon dioxide up to 15%,the weld area and depth/width ratio decreases while rising of carbon dioxide up to 25% causes increasing of weld area and depth/width ratio. It is observed that the weld metal microstructur...
متن کاملSub-Hertz Relative F requency Stabilization of Two-Diode Laser-Pumped Nd : YAG Lasers Locked to a Fabry-Perot Interferometer
Abstrucr-Two-diode laser-pumped Nd : YAG lasers have been frequency stabilized to a commercial 6.327 GHz free spectral range Fabry-Perot interferometer yielding a best-case beatnote linewidth of 330 mHz. In addition, a Fabry-Perot interferometer with a free spectral range of 680 MHz, a linewidth of 25 kHz, and a finesse of 27 500 has been built and when it was substituted in place of the commer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- IEEE Trans. Instrumentation and Measurement
دوره 48 شماره
صفحات -
تاریخ انتشار 1999