Instrumental variability of respiratory blood gases among different blood gas analysers in different laboratories.

نویسندگان

  • M J Kampelmacher
  • R G van Kesteren
  • E K Winckers
چکیده

The aim of this study was to test the hypothesis that differences in oxygen tension (PO2) and carbon dioxide tension (PCO2) values from measurements performed on different blood gas analysers in different laboratories are clinically insignificant. Samples of fresh whole human tonometered blood (PO2 8.1 kPa (60.8 mmHg); PCO2 5.3 kPa (39.9 mmHg)) were placed in airtight glass syringes and transported in ice-water slush. Blood gas analysis was performed within 3.5 h by 17 analysers (10 different models) in 10 hospitals on one day. The mean of the differences between the measured and target values was -0.01+/-0.19 and 0.21+/-0.13 kPa (-0.06+/-1.45 and 1.55+/-1.01 mmHg) for PO2 and PCO2, respectively. The mean of the differences between two samples on one analyser was 0.06+/-0.06 and 0.04+/-0.03 kPa (0.47+/-0.48 and 0.29+/-0.24 mmHg), respectively. For PO2 and PCO2 the interinstrument standard deviations (s(b)) were 0.18 and 0.13 kPa (1.38 and 0.99 mmHg), respectively, whereas the intra-instrument standard deviations (s) were 0.06 and 0.03 kPa (0.47 and 0.26 mmHg), respectively. Both for PO2 and PCO2 the ratios of s(b)2 and s2 were statistically significant (analysis of variance (ANOVA) p<0.001). The standard deviations of a random measurement on a random analyser were 0.19 and 0.14 kPa (1.46 and 1.02 mmHg) for PO2 and PCO2, respectively. We conclude that the variability in measurement of blood gas values among different blood gas analysers, although negligible, depends much more on inter- than intra-instrument variation, both for oxygen tension and carbon dioxide tension. Technical improvements and adequate quality control programmes, including tonometry, may explain why the variability in blood gas values depends mainly on errors in the pre-analytical phase.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of the i-STAT bedside blood gas analyser.

The performance of the i-STAT portable clinical analyser for measuring blood gases and pH was evaluated with reference to a conventional blood gas analyser (ABL520 Radiometer). Ninety-two samples from the routine blood gas analysis laboratory were chosen according to a wide distribution of partial pressure of carbon dioxide (Pa,CO2), partial pressure oxygen (Pa,O2) and pH and then analysed. All...

متن کامل

Assessment of recently developed blood gas analysers: a multicentre evaluation

Providing guidelines for testing expected inaccuracy and imprecision is still a matter under debate. The Expert Panel of the French Society of Clinical Chemistry has developed a protocol, which was based on a comparative multi-centre evaluation of four instruments: the Ciba-Corning 278, the Instrumentation Laboratory 1306, the Nova SP 5 and the ABL 330. The purpose was to evaluate the analytica...

متن کامل

Thermostatic regulation of blood samples in blood gas analysers: results and improved inethod applied to 11 different models

Thermostatic regulation of blood samples in blood gas analysers: results and improv ed inethod a ppli ed to 11 different models

متن کامل

Inter–laboratory precision and relative accuracy of mechanised and nonmechanised systems for blood gas analysis

Introduction In recent years, quality control has been extended to an everincreasing number of biochemical parameters. Its application to blood-gas analysis is complicated by two main factors: the need for reliable, reproducible quality control materials and the variability of calibration standards among the different clinical departments using blood gas apparatus ]. Moreover, automatic analyse...

متن کامل

ارزیابی وضعیت گازهای خون شریانی در شرایط هیپوباریک و مقایسه آن با شرایط نرمال در خلبانان جنگنده شکاری

Background and purpose : Arterial blood gases ( Arterial blood gas [ABG] ) One of the most important Laboratory tests to determine the status PH the amount of oxygen and carbon dioxide blood levels of bicarbonate. Also, hemoglobin and serum lactate and electrolytes and also won the Test . Height and air pressure can vary on ABG and its surface, low pressure conditions at high altitude pilots pl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 10 6  شماره 

صفحات  -

تاریخ انتشار 1997