Ground Fault Current Distribution When a Ground Fault Occurs in HV Substations Located in an Urban Area
نویسنده
چکیده
The paper presents a method of determination of ground fault current distribution when HV (high voltage) substations are located in urban or suburban areas, or where many relevant data necessary for determination of this distribution are uncertain or completely unknown. The problem appears as a consequence of the fact that many of urban metal installations are situated under the surface of the ground and cannot be visually determined or verified. On the basis of on-the-site measurements, the developed method enables compensating all deficiencies of the relevant data about metal installations involved with the fluctuating magnet field appearing around and along a feeding power line during an unbalanced fault. The presented analytical procedure is based on the fact that two measurable quantities, currents in one phase conductor and in one neutral line conductor, cumulatively involve the inductive effects of all, known and unknown surrounding metal installations. Once, this quantity has been determined, the problem of determination of different parts of a ground fault current becomes solvable by using a relatively simple calculation procedure. The presented quantitative analysis indicates at the benefits that can be obtained by taking into account the presence of surrounding metal installations.
منابع مشابه
Seismicity of Batubesi Dam at Sorowako Region Based on Earthquake Data and Microtremor Measurement
Batubesi Dam which is located in Sorowako region in the middle part of Sulawesi island had been designed with seismic coefficient about 0.20g. The region constitutes an active earthquake zone with the recurrence frequency and magnitude of the earthquake are relatively high. The region is located on and active fault zone due to lateral fault movement (strike-slip) of Matano fault, Palukoro fault...
متن کاملActive length of cable lines with uncoated metal sheaths as long grounding conductors
Power cables that have sheaths, usually lead, and are manufactured with bitumen impregnated hessian which degrades over time, act as long grounding electrodes or inject fault current directly into the surrounding soil. As a consequence of this, the MV lines made of this type of cable spontaneously form a very large and complex grounding system around the high-voltage/medium-voltage (HV/MV) dist...
متن کاملبررسی اثر پارامترهای خاص گسلش و موقعیت مکانی ساختگاه بر مشخصات پالس حوزه نزدیک گسل
The characteristics of near-fault ground motion are investigated considering heterogeneous slip distribution on the fault plane. Areas on the fault plane with large slip in compare with the average slip on the fault are known as asperity. The characteristics of strong ground motions in near-fault area are strongly affected by faulting parameters such as asperity location, maximum slip of asperi...
متن کاملInfluence of Seismic Pounding on RC Buildings with and without Base Isolation System Subject to Near-Fault Ground Motions
Building pounding occurs between two adjacent buildings with small gap or without sufficient separation distance. It leads to damage buildings during earthquake due to impact. Many researchers have investigated building pounding based on impact force reduction and energy dissipation increase, when two buildings collide with each other. In numerical investigations, using specific link element, i...
متن کاملInvestigation of forward directivity effects on design spectra of industrial complexes near Assaluyeh fault
Recorded ground motions in near fault region have completely distinct nature from others that recorded in far field of the fault. Near source outcomes cause much of the seismic energy to appear in a single large and long period pulse at the beginning of the velocity record. Assaluyeh complex is located near the reverse Assaluyeh fault that is a segment of Mountain Front Fault. This complex cont...
متن کامل