Conversion of Signals from Ion-specific Electrodes to Linear Concentrations.
نویسنده
چکیده
This paper describes the assembly (from commercially available components) of an antilog converter, which transforms the output signals of ion-specific electrodes to ionic concentrations suitable for a linear recorder. It responds linearly to cation concentrations from 10 mum to at least 10 mm and can be used for electrodes kept at any temperatures (0 to 50 C). The leakage of K(+) from a unicellular algae (Chlorella sorokiniana) can be induced by Triton X-100, heating, or suspension in a tris buffer and is used to demonstrate the operation of this device.
منابع مشابه
Interpretation of Electrochemical Noise Signals Arising from Symmetrical and Asymmetrical Electrodes Made of Polypyrrole Coated Mild Steel
This article applies the standard deviation of partial signal (SDPS) plots of electrochemical noise (EN) current signals originating from corrosion events on the symmetrical and asymmetrical electrodes made of uncoated and polypyrrole (PPy)-coated mild steel alloy in 4000 ppm NaCl+1000 ppm NaNO2 solution. Signal recording was performed after 30, 60, 90 min and 24 h from immersion...
متن کاملComparison of the vanadyl-selective electrodes prepared by sol–gel and PVC membrane techniques
Sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of VO2+ in aqueous solutions. The sol-gel and PVCmembrane electrodes exhibited linear response with Nernstian slopes of 29.3 and 28.4 mV perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...
متن کاملQuantative Evaluation of the Efficiency of Facial Bio-potential Signals Based on Forehead Three-Channel Electrode Placement For Facial Gesture Recognition Applicable in a Human-Machine Interface
Introduction: Today, facial bio-potential signals are employed in many human-machine interface applications for enhancing and empowering the rehabilitation process. The main point to achieve that goal is to record appropriate bioelectric signals from the human face by placing and configuring electrodes over it in the right way. In this paper, heuristic geometrical position and configuration of ...
متن کاملIon Current Simulation During the Post Flame Period in SI Engines
The application of ion current signals is one of the most recent approaches in engine management systems. By applying a small constant DC voltage across the electrodes of the spark plug and measuring the current through the electrode gap, the state of gas may be measured and investigated. In this paper a computer code is developed in order to analyze the state of gas during the combustion p...
متن کاملLinearity and stability of the AVL and Nova magnesium and calcium ion-selective electrodes.
We studied the stability and linearity of the AVL and Nova Mg and Ca ion-selective electrodes and the relation between the ionized Ca and ionized Mg results reported by each analyzer. The response of the electrodes to different concentrations of Mg and Ca was determined for saline solutions, aqueous solutions, and serum samples. The electrodes from both manufacturers demonstrated acceptable sta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال: