Comparison of the Phoenix automated system, the Etest method and broth microdilution in determining temocillin susceptibility of Enterobacteriaceae.

نویسندگان

  • Trupti A Patel
  • Rachel Dilley
  • Alan Williams
  • Gemma L Vanstone
  • Indran Balakrishnan
چکیده

Sir, Temocillin, a semi-synthetic 6-a-methoxy derivative of ticarcillin, has been shown to be clinically efficacious in infections caused by extended-spectrum b-lactamase (ESBL)and AmpC-producing Enterobacteriaceae. It is licensed in the UK for bacteraemia, urinary tract infections (UTIs) and lower respiratory tract infections where susceptible Gram-negative bacteria are suspected or confirmed. Currently, only the BSAC has defined temocillin breakpoints for Enterobacteriaceae (susceptible if MIC ≤8 mg/L for systemic infections and ≤32 mg/L for UTIs). Here, we report a comparison of three temocillin susceptibility testing methodologies [BD PhoenixTM Automated Microbiology System (instrument version 5.15A, software version 6.01A/V5.15A) (Becton Dickinson, Oxford, UK), Etest (AB Biodisk, Solna, Sweden) and broth microdilution (BMD)]. Our data indicate that, whereas the level of agreement for ‘susceptible’ results is excellent, the Phoenix system overcalls temocillin non-susceptibility. A total of 281 consecutive clinical Enterobacteriaceae isolates from distinct patients were collected from urine, blood culture, fluid, respiratory and tissue specimens. Isolates comprised Escherichia coli (194), Klebsiella pneumoniae (19), Proteus mirabilis (16), Enterobacter cloacae (9), Serratia marcescens (7), Citrobacter koseri (6), Enterobacter aerogenes (5), Citrobacter freundii (4), Morganella morganii (4), Klebsiella oxytoca (3), Proteus vulgaris (3), Citrobacter farmeri (2), Pantoea agglomerans (2), Serratia liquefaciens (2), Citrobacter braakii (1), Enterobacter gergoviae (1), Kluyvera sp. (1), Providencia rettgeri (1) and Raoultella ornithinolytica (1). Twenty-seven (9.6%) were ESBL producers, 16 (5.7%) were inducible AmpC b-lactamase producers and 8 (2.8%) were derepressed AmpC b-lactamase producers. Identification and susceptibility testing were performed on overnight cultures using the BD PhoenixTM AP instrument (automated nephelometry) and the BD PhoenixTM Automated Microbiology System (instrument version 5.15A, software version 6.01A/ V5.15A) with Gram-negative Phoenix panels (NMIC-84). Temocillin MICs were also determined by BMD in cation-adjusted Mueller– Research letters

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Temocillin disc diffusion susceptibility testing by EUCAST methodology.

Sir, Temocillin is a semi-synthetic b-lactam antibiotic which is the 6-a-methoxy derivative of ticarcillin. It is a narrow-spectrum agent and its activity is almost exclusively limited to the Enterobacteriaceae—it is not effective against Gram-positive organisms, anaerobes or Pseudomonas aeruginosa. As temocillin is highly stable against hydrolysis by b-lactamases, including extendedspectrum an...

متن کامل

Pharmacokinetics of maraviroc administered at 150 mg once daily in association with lopinavir/ritonavir in HIV-positive treatment-naive patients.

and these results were considered the reference standard against which all other results were compared. Temocillin Etests were used according to the manufacturer's instructions. Susceptibility to temocillin using the Phoenix system was determined according to BSAC breakpoints for Enterobacteriaceae for systemic infections (susceptible if MIC ≤8 mg/L). 3 If the Etest or Phoenix results were with...

متن کامل

Evaluation of vancomycin susceptibility testing for methicillin-resistant Staphylococcus aureus: comparison of Etest and three automated testing methods.

We evaluated the ability of four commercial MIC testing systems (MicroScan, Vitek 2, Phoenix, and Etest) to detect vancomycin MIC values of ≤1 to ≥2 in 200 methicillin-resistant Staphylococcus aureus (MRSA) strains compared to the Clinical and Laboratory Standards Institute broth microdilution (BMD) reference methods. Compared to the BMD method, absolute agreement (0 ± dilution) was highest for...

متن کامل

In vitro susceptibility testing of filamentous fungi: comparison of Etest and reference microdilution methods for determining itraconazole MICs.

The performance of the Etest for itraconazole susceptibility testing of 50 isolates of filamentous fungi was assessed in comparison with the National Committee for Clinical Laboratory Standards (NCCLS) proposed standard microdilution broth method. The NCCLS method employed RPMI 1640 broth medium, and MICs were read after incubation for 48 h at 35 degrees C. Etest MICs were determined with RPMI ...

متن کامل

Comparison of broth microdilution, agar dilution, and Etest for susceptibility testing of doripenem against gram-negative and gram-positive pathogens.

The susceptibility of 513 clinical isolates to doripenem was determined by broth microdilution, agar dilution, and Etest. Overall agreements for Etest and agar dilution MIC values compared to reference broth microdilution at +/-1 log(2) dilution were 88% and 94%, respectively. Etest MIC values demonstrated 98% agreement within +/-2 log(2) dilutions compared to the reference broth microdilution ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of antimicrobial chemotherapy

دوره 68 7  شماره 

صفحات  -

تاریخ انتشار 2013