Comparison of radioimmunoassay with a new immunofluorescent method (FIAX) for measuring tobramycin in serum.
نویسندگان
چکیده
A new immunofluorescent method (FIAX) was compared with a radioimmunoassay procedure for the determination of tobramycin serum concentrations. When assaying three tobramycin control sera repeatedly, within-run and run-to-run variations by the FIAX method were all within acceptable limits, and no statistically significant differences were found. Results of 155 sera from patients who had been treated with tobramycin showed a correlation coefficient of 0.93 between the two methods. The FIAX method represents another practical alternative for determining tobramycin serum levels.
منابع مشابه
Values of the U.S. National Reference Serum for human antibodies to native DNA obtained with commercial immunoassays for anti-DNA in systemic lupus erythematosus.
The Arthritis Foundation and the Centers for Disease Control have recently prepared a "U.S. National Reference Serum" for human antibodies to native DNA. We tested this serum with 13 commercial assays for antibodies to native DNA, to permit comparisons of the values obtained in each test. Titers ranged from 10 to 2560 in Crithidia luciliae immunofluorescence assays. The serum produced 794 int. ...
متن کاملTwo immunofluorescent methods compared with a radial immunodiffusion method for measurement of serum immunoglobulins.
We found high correlations when the values for immunoglobulins G, A, and M, obtained from the analysis of a group of 50 or more human sera by a measured-time radial immunodiffusion method, were compared to values found by two new commercial immunofluorescent methods. The Fiax and the Immuno-Fluor systems make use of fluorescently labeled antibodies and solid-phase immunoadsorbents and off...
متن کاملEvaluation of a method for enzymic radiochemical assay of tobramycin and amikacin in serum.
This enzymic radiochemical procedure for measuring tobramycin and amikacin in serum is based on the transfer of the 14C-acetyl group from [14C]acetyl-coenzyme A to the 6' nitrogen atom of the drug by the enzyme kanamycin 6'-acetyltransferase (EC 2.3.1.55). The transfer, stoichiometric and quantitative, is complete after 10-min incubation at 37 degrees C. The labeled acetylaminoglycoside is adso...
متن کاملQuantitation of serum gentamicin concentration by a solid-phase immunofluorescence method.
We describe the use of a solid-phase immunofluorescence method (FIAX system) for measuring drug concentrations, specifically gentamicin, in serum or plasma. Antibody to gentamicin is immobilized on a polymeric surface. This Sampler is immersed in a mixture of serum standard or unknown and a buffered solution of fluorescent-labeled gentamicin. After 30 min, the fluorescence of the specifically b...
متن کاملAn enzymatic radioassay for gentamicin.
An enzymatic, radiochemical assay procedure for measuring serum gentamicin by use of gentamicin 3-acetyl-transferase and [acetyl-14C]acetyl-Coenzyme A is described and evaluated. The enzyme stoichiometrically and quantitatively transfers a radioactive label to the analyte during a 10-min incubation at 37 degrees C. The labeled gentamicin is then absorbed onto phosphocellulose paper discs, which...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Antimicrobial agents and chemotherapy
دوره 21 1 شماره
صفحات -
تاریخ انتشار 1982