Cyclotron-resonance maser in a periodically loaded quadrupole transmission line.

نویسندگان

  • Y Leibovitch
  • E Jerby
چکیده

A cyclotron-resonance maser (CRM) is implemented in a periodic quadrupole waveguide. The device oscillates at the fundamental and high harmonics of the cyclotron frequency. This CRM employs a tenuous low-energy electron beam ( approximately 10 keV, 0.2 A). The periodic structure consists of an array of disks along the quadrupole transmission line, hence it combines both azimuthal and axial periodicities. This waveguide responds as a band-pass filter (BPF) with uniformly spaced passbands. The CRM is tuned to operate when the cyclotron harmonic frequencies coincide with the waveguide passbands. Microwave emission is observed at the first passband ( approximately 2.4 GHz), and simultaneously at the second and third harmonics in the corresponding BPF passbands ( approximately 4.9 and approximately 7.4 GHz, respectively). A polarized detector reveals the circular polarization of the em wave inside the tube. The results of this experiment may lead to the development of novel CRM harmonic generators and CRM arrays.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Normal and anomalous Doppler effects in a dielectric-loaded stripline cyclotron-resonance maser oscillator

The slow-wave cyclotron-resonance master ~CRM! oscillator experiment presented in this paper produces output signals that correspond to normal and anomalous Doppler shifts. The table-top low-voltage (,10 kV! CRM device consists of a double stripline waveguide. The metal strips are loaded by dielectric slabs; thus the waveguide supports slow waves with different phase velocities in odd and even ...

متن کامل

Pfc/ja-85-4 Free Electron Laser or Cyclotron Maser Instability?

An analysis of recent free electron laser experiments in combined wiggler and strong axial magnetic fields shows that near resonance, Q,,=kwv,,, the proximity of the cyclotron maser instability precludes an unambiguous identification of the radiation mechanism ( 2,, is the cyclotron frequency in the axial field, kw is the wiggler wavenumber, and v,, the axial electron velocity).

متن کامل

Hyperbolic transmission-line metamaterials

Articles you may be interested in Omega transmission lines with applications to effective medium models of metamaterials Experimental verification of field rotating with invisibility by full tensor transmission-line metamaterials Appl. Dark Schrödinger solitons and harmonic generation in left-handed nonlinear transmission line Anomalous reflection and refraction in anisotropic metamaterial real...

متن کامل

Pulsed electromagnetic field at frequency and intensity resembling potassium ion cyclotron resonance selectively impairs breast cancer cell through apoptosis

Introduction: Breast cancer (BC) is the most common women cancer worldwide. Radiotherapy and chemotherapy are the two common treatment options but these techniques suffer low selectivity and adverse effects on surrounding normal tissues. Non- ionizing pulsed electromagnetic fields (PEMFs) in ultra-narrow band frequency and intensity have shown anticancer effects. Changing potas...

متن کامل

Cyclotron-resonance maser in a magnetic mirror.

A cyclotron-resonance maser (CRM) experiment is performed in a high-gradient magnetic field using a low-energy electron beam ( approximately 10 keV/1 A). The magnetic field exceeds 1.63 T, which corresponds to a 45-GHz cyclotron frequency. The CRM radiation output is observed in much lower frequencies, between 6.6 and 20 GHz only. This discrepancy is explained by the finite penetration depth of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics

دوره 60 2 Pt B  شماره 

صفحات  -

تاریخ انتشار 1999