A Novel Indicator Reaction for the Catalytic Determination of V(V) at ppb Levels by the Kinetic Spectrophotometric Method

نویسندگان

  • Halil İbrahim Ulusoy
  • Ramazan Gürkan
چکیده

A novel sensitive and relatively selective kinetic method is presented for the determination of V(V), based on its catalytic effect on the oxidation reaction of Ponceau Xylydine by potassium bromate in presence of 5-sulfosalicylic acid (SSA) as activator. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of Ponceau Xylydine at 640 nm between 0.5 to 7 min (the fixed time method) in H3PO4 medium at 25 oC. The effect of various parameters such as concentrations of H3PO4, SSA, bromate and Ponceau Xylydine, temperature and ionic strength on the rate of net reaction were studied. The method is free from most interferences, especially from large amounts of V(IV). The decrease in absorbance is proportional to the concentration of V(V) over the entire concentration range tested (1–15 ng mL−1) with a detection limit of 0.46 ng mL–1 (according to statistical 3Sblank/k criterion) and a coefficient of variation (CV) of 1.8% (for ten replicate measurement at 95% confidence level). The proposed method suffers few interferences such as Cr(VI) and Hg(II) ions. The method was successfully applied to the determination of V(V) in tap water, drinking water, bottled mineral water samples and a certified standard reference material such as SRM-1640 with satisfactory results. The vanadium contents of water samples were also determined by FAAS for a comparison. The recovery of spiked vanadium(V) was found to be quantitative and the reproducibility was satisfactory. It was observed that the results of the SRM 1640 were in good agreement with the certified value.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trace Amounts Determination of Vanadium (V) Using a New Kinetic-Catalytic Reaction System

This study describes a new simple, sensitive and selective catalytic kinetic spectrophotometricmethod for the determination of vanadium (V). The method is based upon the catalytic effect ofvanadium (V) on the oxidation of Carminic acid by bromate in sulfuric acid media. The reaction wasfollowed spectrophotometrically by measuring the decrease in absorbance at 490 nm and thedependence of sensiti...

متن کامل

SPECTROPHOTOMETRIC REACTION RATE METHOD FOR THE DETERMINATION OF NITRITE BY CATALYTIC ACTION ON NILE BLUE A BROMATE REACTION

A kinetic method developed for the determination of ultra-trace amounts of nitrite based on its catalytic effect on the reaction between potassium bromate and Nile blue A in strongly acidic media is reported. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of Nile blue A at 645 nm by the fixed-time method. The decrease in absorbance during the first...

متن کامل

Catalytic Kinetic Determination of Silver through its Catalytic Effect on Congo Red-Peroxodisulphate Reaction

A kinetic-spectrophotometric procedure is reported for determination of trace amounts of Ag(I). This method is based on catalytic effect of silver ion on the oxidation of congo red by potassium peroxodisulphate at pH=3.4 and 30 oC in the presence of 1,10-phenanthroline as an activator. The reaction was followed spectrophotometrically by measuring the rate of change in absorbance ...

متن کامل

Application of Thionine Dye for Highly Sensitive and Selective Catalytic kinetic Determination of Osmium

Anew, highly sensitive and selective catalytic kinetic method (CKM) for determination of osmium (VIII) has been established based on its catalytic effect on the oxidation of thionine dye by hydrogen peroxide in alkaline medium. The reaction has been followed spectrophotometrically by measuring the decrease in the absorbance band of thionine at 600 nm. Under the optimum conditions, the proposed ...

متن کامل

Sub-ppm determination of uric acid using a sensitive kinetic-catalytic reaction system

A sensitive and selective kinetic-spectrophotometric method was developed for the determination of trace amounts of uric acid. The method is based on the inhibitory effect of uric acid on the oxidation of Janus Green by bromate in the presence of sulfuric acid. The reaction was followed spectrophotometrically by measuring the absorbance at 518 nm using the fixed-time method. Under optimum exper...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010