Insert dissociation after fixed bearing PS constrained Genesis II total knee arthroplasty. A case series of nine patients.
نویسندگان
چکیده
Dissociation of the polyethylene insert after fixed bearing posterior stabilized Genesis II total knee arthroplasty has been rarely described. We present a case series of nine patients with a dissociation of the insert within a period of two years after surgery. Revision surgery was performed in all patients. In this report we discuss clinical presentation, patient characteristics and possible etiologies for tibial insert dissociation seen in the presented cases. In conclusion, tibial insert dissociation does not lead to a uniform clinical presentation. Therefore, in this point of view regular physical examination and imaging after TKA regardless the presence of symptoms seems to be indicated.
منابع مشابه
Early Clinical Outcomes of a New Posteriorly Stabilized Total Knee Arthroplasty Prosthesis: Comparisons with Two Established Prostheses
Purpose We sought to determine whether early clinical performance of new posterior stabilized (PS) knee system, the Vega-PS (Aesculap), is better than that of two established total knee arthroplasty (TKA) prostheses, the E.motion-PS (Aesculap) and the Genesis II (Smith & Nephew) in terms of functional outcomes, patient satisfaction, and incidence of adverse events. Materials and Methods We co...
متن کاملThe Scorpio Total Knee Prosthesis with a mobile bearing or fixed bearing polyethylene insert. A randomized clinical trial compa
INTRODUCTION: Total knee arthroplasty (TKA) has become a standard operative procedure to relieve pain and restore function in patients with osteoarthritis. Polyethylene (Pe) mobile bearing (MB) inserts have been developed to minimize implant wear, prolong prosthesis survival and evoke less anterior knee pain due to better self-alignment. The aim of this study was to compare the clinical, radiol...
متن کاملTraumatic Dislodgement of Tibial Polyethylene Insert after a High-Flex Posterior-Stabilized Total Knee Replacement
Many pathologic entities can produce a painful total knee replacement (TKR) that may lead to potential prosthetic failure. Polyethylene insert dissociation from the tibial baseplate has been described most frequently after mobile-bearing and cruciate-retaining TKRs. However, only 3 tibial insert dislocations in primary fixed-bearing High-Flex posterior-stabilized TKRs have been reported. We pre...
متن کاملThe Influence of Contemporary Knee Design on High Flexion Ii: a Kinematic Comparison with the Normal Knee
Although Total Knee Arthroplasty (TKA) surgery enjoys 90% of outcomes with good to excellent results, some patients have difficulty adjusting their gait to accommodate the new articulations inherent in contemporary implant designs. Paradoxical motions inclusive of anterior sliding and lateral pivot are examples of aberrant TKA kinematics. This paper compares the motion of six contemporary TKA d...
متن کاملVisualization of femorotibial contact in total knee arthroplasty using X-ray fluoroscopy.
The purpose of this study was to build a visualization technique of the femorotibial contact in fixed-bearing total knee arthroplasty (TKA) using X-ray fluoroscopy, and to apply this technique to a TKA patient during dynamic motion. In vivo kinametcis of the metallic knee implant was determined using a 2D/3D registration technique, which uses computer assisted design (CAD) model of the implant ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Acta orthopaedica Belgica
دوره 81 4 شماره
صفحات -
تاریخ انتشار 2015