Real-time wide-angle sector echocardiography: atrioventricular canal defects.

نویسندگان

  • D J Hagler
  • A J Tajik
  • J B Seward
  • D D Mair
  • D G Ritter
چکیده

Real-time 800 phased-array two-dimensional sector echocardiography was used in 44 patients with atrioventricular (AV) canal defect. Anatomic details were surgically confirmed in 33. The apex view allowed visualization of atrial and ventricular portions of complete AV canal defects, with the common AV valve structures between the defects. The apex view also allowed us to differentiate divided and undivided, attached and free-floating common anterior valve leaflets to distinguish types A, B, and C complete AV canal defects. With the apex view, the ostium primum atrial septal defect and the attachment of the AV valve to the crest of the ventricular septum were observed in partial AV canal defect. Short-axis views revealed the cleft in the anterior leaflet of the mitral valve. The rapid and precise definition of anatomic details by this method has eliminated many of the difficulties in diagnosing this defect by M-mode echocardiography.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DICROTIC PULSE/Orchard and Craige

15. Dillon JC, Weyman AE, Feigenbaum H, Eggleton RC, Johnston K: Cross-sectional echocardiographic examination of the interatrial septum. Circulation 55: 115, 1977 16. Lieppe W, Scallion R, Behar VS, Kisslo JA: Two-dimensional echocardiographic findings in atrial septal defect. Circulation 56: 447, 1977 17. Hagler DJ, Tajik AJ, Seward JB, Mair DD, Ritter DG: Realtime wide-angle sector echocardi...

متن کامل

Double-outlet right ventricle: wide-angle two-dimensional echocardiographic observations.

M-mode echocardiographic delineation of double-outlet right ventricle (DORV) has relied primarily on the demonstration of mitral-semilunar valve discontinuity--a feature that requires an interpretation of spatial anatomic relationships. Thirty-six patients with DORV were examined by wide-angle real-time two-dimensional echocardiography. Anatomic diagnosis was established by surgery in 28 patien...

متن کامل

Mirror Image Gerbode or Partial Atrioventricular Canal Defect?

Gebode defect, that can accurately be treated surgical repair, is defined as a true communication between left ventricle and right atrium. A 74-year-old woman with a worsening history of ortophnea and peripheral edema was hospitalised. A communication between right atrium and left ventricle was diagnosed using transeusophageal echocardiography. The defect was repaired and mitral valve was repla...

متن کامل

Two-dimensional echocardiographic assessment of common atrioventricular valves in univentricular hearts.

Twelve patients with univentricular heart and common atrioventricular valve were identified by two-dimensional echocardiography. Seven had an ostium primum atrial septal defect and five a common atrium. The common atrioventricular valve had the appearance of a free floating anterior leaflet flanked by two lateral leaflets. The position of the rudimentary chamber in relation to the atrioventricu...

متن کامل

Complete atrioventricular canal

Complete atrioventricular canal (CAVC), also referred to as complete atrioventricular septal defect, is characterised by an ostium primum atrial septal defect, a common atrioventricular valve and a variable deficiency of the ventricular septum inflow. CAVC is an uncommon congenital heart disease, accounting for about 3% of cardiac malformations. Atrioventricular canal occurs in two out of every...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 59 1  شماره 

صفحات  -

تاریخ انتشار 1979