Four lateral mass screw fixation techniques in lower cervical spine following laminectomy: a finite element analysis study of stress distribution

نویسندگان

  • Mingzhi Song
  • Zhen Zhang
  • Ming Lu
  • Junwei Zong
  • Chao Dong
  • Kai Ma
  • Shouyu Wang
چکیده

BACKGROUND Lateral mass screw fixation (LSF) techniques have been widely used for reconstructing and stabilizing the cervical spine; however, complications may result depending on the choice of surgeon. There are only a few reports related to LSF applications, even though fracture fixation has become a severe complication. This study establishes the three-dimensional finite element model of the lower cervical spine, and compares the stress distribution of the four LSF techniques (Magerl, Roy-Camille, Anderson, and An), following laminectomy -- to explore the risks of rupture after fixation. METHOD CT scans were performed on a healthy adult female volunteer, and Digital imaging and communication in medicine (Dicom) data was obtained. Mimics 10.01, Geomagic Studio 12.0, Solidworks 2012, HyperMesh 10.1 and Abaqus 6.12 software programs were used to establish the intact model of the lower cervical spines (C3-C7), a postoperative model after laminectomy, and a reconstructive model after applying the LSF techniques. A compressive preload of 74 N combined with a pure moment of 1.8 Nm was applied to the intact and reconstructive model, simulating normal flexion, extension, lateral bending, and axial rotation. The stress distribution of the four LSF techniques was compared by analyzing the maximum von Mises stress. RESULT The three-dimensional finite element model of the intact C3-C7 vertebrae was successfully established. This model consists of 503,911 elements and 93,390 nodes. During flexion, extension, lateral bending, and axial rotation modes, the intact model's angular intersegmental range of motion was in good agreement with the results reported from the literature. The postoperative model after the three-segment laminectomy and the reconstructive model after applying the four LSF techniques were established based on the validated intact model. The stress distribution for the Magerl and Roy-Camille groups were more dispersive, and the maximum von Mises stress levels were lower than the other two groups in various conditions. CONCLUSION The LSF techniques of Magerl and Roy-Camille are safer methods for stabilizing the lower cervical spine. Therefore, these methods potentially have a lower risk of fixation fracture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Biomechanical Comparison of Three Different Posterior Fixation Constructs Used for C6–C7 Cervical Spine Immobilization: A Finite Element Study

The intralaminar screw construct has been recently introduced in C6-C7 fixation. The aim of the study is to compare the stability afforded by three different C7 posterior fixation techniques using a three-dimensional finite element model of a C6-C7 cervical spine motion segment. Finite element models representing three different cervical anchor types (C7 intralaminar screw, C7 lateral mass scre...

متن کامل

A Novel Anterior Transpedicular Screw Artificial Vertebral Body System for Lower Cervical Spine Fixation: A Finite Element Study.

A finite element model was used to compare the biomechanical properties of a novel anterior transpedicular screw artificial vertebral body system (AVBS) with a conventional anterior screw plate system (ASPS) for fixation in the lower cervical spine. A model of the intact cervical spine (C3-C7) was established. AVBS or ASPS constructs were implanted between C4 and C6. The models were loaded in t...

متن کامل

Decompressive cervical laminectomy and lateral mass screw-rod arthrodesis. Surgical analysis and outcome

BACKGROUND This study evaluates the outcome and complications of decompressive cervical Laminectomy and lateral mass screw fixation in 110 cases treated for variable cervical spine pathologies that included; degenerative disease, trauma, neoplasms, metabolic-inflammatory disorders and congenital anomalies. METHODS A retrospective review of total 785 lateral mass screws were placed in patients...

متن کامل

Posterior cervical decompressive laminectomy and lateral mass screw fixation.

OBJECTIVE To review the results and complications of cervical decompressive laminectomy and lateral mass screw fixation. METHODS This retrospective study was carried out between October 2006 and January 2010 at King Abdullah University Hospital, Irbid, Jordan. Over 40 months, 405 lateral mass screws were placed in 50 patients aged 22-65 years (17 females, and 33 males) for variable cervical p...

متن کامل

Posterior Fixation Techniques in the Subaxial Cervical Spine

This article reviews the historical context, indications, techniques, and complications of four posterior fixation techniques to stabilize the subaxial cervical spine. Specifically, posterior wiring, laminar screw fixation, lateral mass fixation, and pedicle screw fixation are among the common methods of operative fixation of the subaxial cervical spine. While wiring and laminar screw fixation ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2014