Salivary gland scintigraphy: the use of semiquantitative analysis for uptake and clearance.

نویسندگان

  • Issa Loutfi
  • Madhusoodanan K Nair
  • Ali K Ebrahim
چکیده

OBJECTIVE Quantitative analysis of (99m)Tc-pertechnetate salivary gland scintigraphy has been used in the evaluation of salivary gland function, but so far no one method can be considered optimal for this task. In this study, a semiquantitative method providing 2 functional parameters for objective assessment of salivary gland function by scintillation camera imaging was tested. METHODS Twenty-one patients referred for (99m)Tc-pertechnetate thyroid scanning were studied. Two patients with salivary complaints were also included. Dynamic imaging of the anterior head using a scintillation camera was started after a bolus intravenous injection of 185 MBq (5 mCi) (99m)Tc-pertechnetate at 1 frame per 30 s for 30 min. At 15 min after injection, diluted lemon juice was administered orally. Analysis of the dynamic study included time-activity curves of 4 salivary glands (right and left parotid and right and left submandibular). Two parameters of function were defined: uptake rate, taken as the value of the initial slope of the time-activity curve, and washout fraction, which was the relative mobilizable radioactivity from each salivary gland after ingestion of the sialogogue. A parametric image of the washout fraction was also generated. RESULTS The images showed gradual uptake in the parotid and submandibular glands. Washout was noted immediately after ingestion of the lemon juice. The pattern of the time-activity curve in all glands showed an early fast-rising part followed by a slow-rising component to nearly a plateau within 6-10 min after injection. The mean value of the uptake rate parameter was 0.10 +/- 0.09 cps/s. There was no significant difference between the parotid and submandibular glands or the right and left sides. Uptake in the parotid gland was 1.5-2 times that in the submandibular gland. The washout fraction was 1.40 +/- 1.60 for the parotid glands and 0.77 +/- 0.41 for the submandibular glands (P = 0.005). CONCLUSION The quantitative analysis method including the uptake rate and the washout fraction parameters would enable objective assessment of salivary function and provide a reproducible means for follow-up of functional impairment in certain diseases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved quantification of salivary gland scintigraphy by means of factor analysis

Introduction: In this study the automatic separation of oral and salivary gland activity and spontaneous secretion by means of factor analysis for quantitative salivary gland scintigraphy is introduced. Methods: After intravenous administration of 99mTc sodium pertechnetate, dynamic scintigraphy was performed. 20 minutes after tracer application 2 ml of lemon juice was delivered to stimulate t...

متن کامل

Salivary Gland Scintigraphy in Patients with Sjogren’s Syndrome: A local Experience with Dual-tracer

Objective(s): To review the findings of the patients with Sjögren’s syndrome (SS) having technetium-99m-pertechnetate (99mTc-pertechnetate) and gallium-67 citrate (Ga-67) salivary gland scintigraphy in the past eight years.Methods: The patients with SS, who were referred to our department for salivary gland scintigraphy during January 2008-December 2015 were studied using both 99mTc-pertechneta...

متن کامل

Radioprotective effect of thymol against salivary glands dysfunction induced by ionizing radiation in rats

The aim of this study was to investigate the radioprotective effect of thymol as a natural product against salivary glands dysfunction induced by ionizing radiation in rats. The rats were treated with thymol at dose of 50 mg/Kg before exposure to radiation at dose 15Gy. Salivary gland function was evaluated with radioisotope scintigraphy and then salivary gland to background counts ratio was ca...

متن کامل

Radioprotective effect of thymol against salivary glands dysfunction induced by ionizing radiation in rats

The aim of this study was to investigate the radioprotective effect of thymol as a natural product against salivary glands dysfunction induced by ionizing radiation in rats. The rats were treated with thymol at dose of 50 mg/Kg before exposure to radiation at dose 15Gy. Salivary gland function was evaluated with radioisotope scintigraphy and then salivary gland to background counts ratio was ca...

متن کامل

Quantitative assessment of salivary gland function by radioisotopic scanning in a randomized trial of Pilocarpine for prevention of radiation induced Xerostomia [Persian]

Introduction: Radioisotope scanning is the best method for objective assessment of salivary gland function. Thus, it was used in a randomized trial of concomitant pilocarpine for assessment of radiation-induced xerostomia, in addition to subjective evaluation by an approved questionnaire and objective standard xerostomia grading. Methods: Patients randomized in placebo-controlled trial of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 31 2  شماره 

صفحات  -

تاریخ انتشار 2003