A study on electrode gels for skin conductance measurements.

نویسندگان

  • Christian Tronstad
  • Gorm Krogh Johnsen
  • Sverre Grimnes
  • Ørjan G Martinsen
چکیده

Low-frequency skin conductance is used within several clinical applications and is mainly sensitive to sweating and the moisture content of the stratum corneum, but also how electrodes introduce changes in the electrical properties. Four electrode gels were investigated with regard to sorption characteristics and electrical properties. Skin conductance time series were collected from 18 test subjects during relaxation, exercise and recovery, wearing different pairs of electrodes contralaterally on the hypothenar and the T9 dermatome. Pressure test was applied on the T9 electrodes. Impedance frequency sweeps were taken on the T9 electrodes the same day and the next, parameterized to the Cole model. ANOVA on the initial skin conductance level change, exercise response amplitude, recovery offset and pressure-induced changes revealed significant differences among gel types. The wetter gels caused a higher positive level change, a greater response amplitude, larger recovery offset and greater pressure-induced artifacts compared to the solid gels. Sweating on the T9 site led to negative skin conductance responses for the wetter gels. Correlations were found between the desorption measurements and the initial skin conductance level change (hypothenar: R = 0.988 T9: R = 0.901) RM-ANOVA on the Cole parameters revealed a significant decrease in R(s) of the most resistive gel. Clinical implications are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrodermal activity by DC potential and AC conductance measured simultaneously at the same skin site.

BACKGROUND For a long time, DC conductance has been the most important parameter in electrodermal routine measurements. However, DC current flow polarizes the electrodes, electrolyzes the skin, disturbs the measurement of conductance by possible varying electromotive forces (EMFs) in the circuit, and impedes the registration of the skin endosomatic DC potential. METHODS We therefore present a...

متن کامل

Influence of Dimethyl Sulfoxide as a Penetration Enhancer of Piroxicam Gel Through Biological Skin

      Piroxicam is a non-steroidal anti-inflammatory agent which has an extensive use in rheumatic disorders. Since its skin penetration is still a subject for research, the aim of this study was to evaluate the effect of dimethyl sulfoxide on percutaneous penetration of piroxicam gel formulation through skin. In this study, as a model, two types of 0.5% piroxicam new gels, so called red and gr...

متن کامل

Surface Modification of Glassy Carbon Electrode by Ni-Cu Nanoparticles as a Competitive Electrode for Ethanol Electro-Oxidation

In the present study, Nickel-Copper nanoparticles were electrodeposited on glassy carbon electrode (GCE) by using electroplating deposition method. The prepared electrode was characterized by scanning electron microscopy (SEM) and elemental mapping analysis. Results showed that Ni-Cu nanoparticles with a high density are distributed at the surface of the glassy carbon electrode. Subsequentl...

متن کامل

Electrical conductance and electrode area on sound smooth enamel in extracted teeth.

Electrical conductance measurements are being used experimentally to diagnose caries. Current equipment, e.g. the electronic caries monitor (ECM), uses a probe to scan occlusal fissures. For full-mouth examination this method is rather time-consuming. A method with which only one measurement is needed for an entire (occlusal) surface would be preferable. However, the enlargement of the area bei...

متن کامل

Sources of error in AC measurement of skin conductance

Alternating current methods have the potential to improve the measurement of electrodermal activity. However, there are pitfalls that should be avoided in order to perform these measurements in a correct manner. In this paper, we address issues like the choice of measurement frequency, placement of electrodes and the kind of electrodes used. Ignoring these factors may result in loss of measurem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological measurement

دوره 31 10  شماره 

صفحات  -

تاریخ انتشار 2010