Distribution Characteristics of Air-Bone Gaps: Evidence of Bias in Manual Audiometry.

نویسندگان

  • Robert H Margolis
  • Richard H Wilson
  • Gerald R Popelka
  • Robert H Eikelboom
  • De Wet Swanepoel
  • George L Saly
چکیده

OBJECTIVES Five databases were mined to examine distributions of air-bone gaps obtained by automated and manual audiometry. Differences in distribution characteristics were examined for evidence of influences unrelated to the audibility of test signals. DESIGN The databases provided air- and bone-conduction thresholds that permitted examination of air-bone gap distributions that were free of ceiling and floor effects. Cases with conductive hearing loss were eliminated based on air-bone gaps, tympanometry, and otoscopy, when available. The analysis is based on 2,378,921 threshold determinations from 721,831 subjects from five databases. RESULTS Automated audiometry produced air-bone gaps that were normally distributed suggesting that air- and bone-conduction thresholds are normally distributed. Manual audiometry produced air-bone gaps that were not normally distributed and show evidence of biasing effects of assumptions of expected results. In one database, the form of the distributions showed evidence of inclusion of conductive hearing losses. CONCLUSIONS Thresholds obtained by manual audiometry show tester bias effects from assumptions of the patient's hearing loss characteristics. Tester bias artificially reduces the variance of bone-conduction thresholds and the resulting air-bone gaps. Because the automated method is free of bias from assumptions of expected results, these distributions are hypothesized to reflect the true variability of air- and bone-conduction thresholds and the resulting air-bone gaps.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distribution characteristics of normal pure-tone thresholds.

OBJECTIVE This study examined the statistical properties of normal air-conduction thresholds obtained with automated and manual audiometry to test the hypothesis that thresholds are normally distributed and to examine the distributions for evidence of bias in manual testing. DESIGN Four databases were mined for normal thresholds. One contained audiograms obtained with an automated method. The...

متن کامل

A systematic review of the effect of different crimping techniques in stapes surgery for otosclerosis.

OBJECTIVES/HYPOTHESIS To evaluate the effect of crimping techniques in stapes surgery for otosclerosis patients measured by hearing outcomes on pure-tone audiometry. DATA SOURCES PubMed, EMBASE, and the Cochrane Library. METHODS A systematic search was conducted. Studies comparing the effect of different crimping methods on pure-tone audiometric results in patients undergoing stapes surgery...

متن کامل

Clinical validation of the AMTAS automated audiometer.

OBJECTIVE To validate the air- and bone-conduction AMTAS automated audiometry system. DESIGN Prospective study. Test-retest reliability was determined by assessing adults with AMTAS air- and bone-conduction audiometry. Accuracy was determined by comparing AMTAS and manual audiometry conducted on adults. AMTAS testing was conducted in a quiet room and manual audiometry in a sound booth. STUD...

متن کامل

Primary stapedotomy in children with otosclerosis: A prospective study of 41 consecutive cases.

OBJECTIVES/HYPOTHESIS To prospectively evaluate hearing outcomes in children with otosclerosis undergoing primary stapes surgery. STUDY DESIGN A nonrandomized, nonblinded, prospective case series. METHODS Thirty-four consecutive pediatric patients who underwent 41 primary stapedotomies for otosclerosis in a tertiary referral center were included. Patients were included when there was eviden...

متن کامل

Validity of Automated Threshold Audiometry: A Systematic Review and Meta-Analysis.

OBJECTIVES:: A systematic literature review and meta-analysis on the validity (test-retest reliability and accuracy) of automated threshold audiometry compared with the gold standard of manual threshold audiometry was conducted. DESIGN:: A systematic literature review was completed in peer-reviewed databases on automated compared with manual threshold audiometry. Subsequently a meta-analysis wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ear and hearing

دوره 37 2  شماره 

صفحات  -

تاریخ انتشار 2016