A pilot study of reference vibrotactile perception thresholds on the fingertip obtained with Malaysian healthy people using ISO 13091-1 equipment.

نویسندگان

  • Roshada Daud
  • Setsuo Maeda
  • Nur Nazmin Mustafa Kameel
  • Muhamad Yunus Ripin
  • Norazman Bakrun
  • Raemy Md Zein
  • Masaharu Kido
  • Kiyotaka Higuchi
چکیده

The purpose of this paper is to clarify the reference vibrotactile perception thresholds (VPT) for healthy people in Malaysia. The measurement equipment standard, ISO 13091-1, of the vibrotactile perception thresholds for the assessment of nerve dysfunction and the analysis and interpretation of measurements at the fingertips standard, ISO 13091-2, were published in ISO/TC108/SC4/WG8 on 2001 and 2003 individually. In the ISO 13091-2 standard, the reference VPT data were obtained from few research papers. Malaysian people's VPT data don't include to this standard. In Malaysia, when the VPT is using to diagnose of the hand-arm vibration syndrome, the reference VPT data need to compare with the worker's ones. But, Malaysia does not have the reference VPT data yet. So, in this paper, the VPT was measured by using ISO 13091-1 standard equipment to obtain the reference data for Malaysian people. And these data were compared with the ISO reference data on the ISO 13091-2 standard. From the comparison of these data, it was clear that the Malaysian healthy people's VPT data were consistent with the reference data of the ISO 13091-2 standard.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Repeatability of vibrotactile perception thresholds obtained with two different measuring systems.

OBJECTIVES The measurement of vibrotactile perception thresholds (VPTs) on the workers' fingertips is one of the diagnostic methods of the occupational peripheral neuropathies. The aim of the study was to compare the repeatability of VPT measurements in two groups of healthy women with different finger skin temperature, using two different types of measuring systems. MATERIALS AND METHODS One...

متن کامل

Measurements of vibrotactile perception thresholds at the fingertips in Poland.

OBJECTIVES The measurement of vibrotactile perception thresholds (VPTs) at fingertips in workers belongs in Poland among obligatory methods used to diagnose hand-arm vibration syndrome. The aim of the study was to compare vibrotactile perception threshold (VPT) values for healthy subjects using two different types of measuring equipment, i.e. a system designed according to the requirements of t...

متن کامل

[Comparison of vibrotactile thresholds in women obtained with two psychophysical measurement methods].

BACKGROUND The aim of the study was to determine differences between vibrotactile thresholds values in healthy women obtained with two psychophysical methods: the method drafted in ISO standard ISO 13091-1:2001 and the method hitherto used in Poland. MATERIAL AND METHODS Twenty two women (mean age, 37.9 +/- 9.7 years) participated in the study. Vibrotactile perception thresholds were measured...

متن کامل

Effect of changes in finger skin temperature on vibrotactile perception threshold.

OBJECTIVES The purpose of the study was to determine the influence of finger skin temperature on the vibrotactile perception threshold at fingertips, determined according to the method described in ISO 13091-1 standard. MATERIALS AND METHODS The effect of the cooling and warming of hands on vibration perception was investigated in 21 healthy women. Vibration perception measurements were condu...

متن کامل

Vibrotactile perception and effects of short-term exposure to hand-arm vibration.

This study clarifies whether the established frequency weighting procedure for evaluating exposure to hand-transmitted vibration can effectively evaluate the temporary changes in vibrotactile perception thresholds due to pre-exposure to vibration. In addition, this study investigates the relationship between changes of the vibrotactile perception thresholds and the normalized energy-equivalent ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Industrial health

دوره 42 2  شماره 

صفحات  -

تاریخ انتشار 2004