A portable system for collecting anatomical joint angles during stair ascent: a comparison with an optical tracking device
نویسندگان
چکیده
BACKGROUND Assessments of stair climbing in real-life situations using an optical tracking system are lacking, as it is difficult to adapt the system for use in and around full flights of stairs. Alternatively, a portable system that consists of inertial measurement units (IMUs) can be used to collect anatomical joint angles during stair ascent. The purpose of this study was to compare the anatomical joint angles obtained by IMUs to those calculated from position data of an optical tracking device. METHODS Anatomical joint angles of the thigh, knee and ankle, obtained using IMUs and an optical tracking device, were compared for fourteen healthy subjects. Joint kinematics obtained with the two measurement devices were evaluated by calculating the root mean square error (RMSE) and by calculating a two-tailed Pearson product-moment correlation coefficient (r) between the two signals. RESULTS Strong mean correlations (range 0.93 to 0.99) were found for the angles between the two measurement devices, as well as an average root mean square error (RMSE) of 4 degrees over all the joint angles, showing that the IMUs are a satisfactory system for measuring anatomical joint angles. CONCLUSION These highly portable body-worn inertial sensors can be used by clinicians and researchers alike, to accurately collect data during stair climbing in complex real-life situations.
منابع مشابه
Hip, knee, ankle kinematics and kinetics during stair ascent and descent in healthy young individuals.
BACKGROUND Few studies have reported the biomechanical aspects of stair climbing for this ergonomically demanding task. The purpose of this ethically approved study was to identify normal functional parameters of the lower limb during stair climbing and to compare the actions of stair ascent and descent in young healthy individuals. METHODS Thirty-three young healthy subjects, (16 M, 17 F, ra...
متن کاملGait analysis post anterior cruciate ligament reconstruction: knee osteoarthritis perspective.
Individuals with anterior cruciate ligament (ACL) reconstruction are at increased risk to develop knee osteoarthritis (OA). Gait analysis describing kinetics of the lower extremity during walking and stair use (stair ascent and stair descent) can provide insight to everyday dynamic knee joint loading. In this study, we compared lower extremity gait patterns of those with ACL reconstruction (>1 ...
متن کاملStair ascent and descent at different inclinations.
The aim of this study was to investigate the biomechanics and motor co-ordination in humans during stair climbing at different inclinations. Ten normal subjects ascended and descended a five-step staircase at three different inclinations (24 degrees, 30 degrees, 42 degrees ). Three steps were instrumented with force sensors and provided 6 dof ground reactions. Kinematics was analysed by a camer...
متن کاملComparison of Unicompartmental Knee Arthroplasty and Healthy Limb for Knee Moments Generated during Stair Ascent
With improvement of implant design and surgical techniques, use of unicompartmental knee arthroplasty (UKA) has increased recently [1]. This surgery replaces the most damaged knee compartment, either the medial (MED) or lateral (LAT). However, biomechanical evidence to support the efficacy of UKA is still lacking, especially LAT-UKA. Stair ascent is a highdemanding functional activity. Interlim...
متن کامل[Kinematics of Stair Ascent in Children and Adolescents with Autism Spectrum Disorder].
We analyzed kinematics of stair ascent and descent in autistic children and adolescents in comparison with age-matched healthy children and adolescents. Eight healthy adolescents, 6 autistic adolescents, 7 healthy children and 6 autistic children participated in the study. We found that autistic subjects of both groups showed significantly more fluctuations of hip joint angular velocity than ag...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Dynamic Medicine : DM
دوره 8 شماره
صفحات -
تاریخ انتشار 2009