Twofold processing for denoising ultrasound medical images.
نویسندگان
چکیده
Ultrasound medical (US) imaging non-invasively pictures inside of a human body for disease diagnostics. Speckle noise attacks ultrasound images degrading their visual quality. A twofold processing algorithm is proposed in this work to reduce this multiplicative speckle noise. First fold used block based thresholding, both hard (BHT) and soft (BST), on pixels in wavelet domain with 8, 16, 32 and 64 non-overlapping block sizes. This first fold process is a better denoising method for reducing speckle and also inducing object of interest blurring. The second fold process initiates to restore object boundaries and texture with adaptive wavelet fusion. The degraded object restoration in block thresholded US image is carried through wavelet coefficient fusion of object in original US mage and block thresholded US image. Fusion rules and wavelet decomposition levels are made adaptive for each block using gradient histograms with normalized differential mean (NDF) to introduce highest level of contrast between the denoised pixels and the object pixels in the resultant image. Thus the proposed twofold methods are named as adaptive NDF block fusion with hard and soft thresholding (ANBF-HT and ANBF-ST). The results indicate visual quality improvement to an interesting level with the proposed twofold processing, where the first fold removes noise and second fold restores object properties. Peak signal to noise ratio (PSNR), normalized cross correlation coefficient (NCC), edge strength (ES), image quality Index (IQI) and structural similarity index (SSIM), measure the quantitative quality of the twofold processing technique. Validation of the proposed method is done by comparing with anisotropic diffusion (AD), total variational filtering (TVF) and empirical mode decomposition (EMD) for enhancement of US images. The US images are provided by AMMA hospital radiology labs at Vijayawada, India.
منابع مشابه
Biomedical Image Denoising Based on Hybrid Optimization Algorithm and Sequential Filters
Background: Nowadays, image de-noising plays a very important role in medical analysis applications and pre-processing step. Many filters were designed for image processing, assuming a specific noise distribution, so the images which are acquired by different medical imaging modalities must be out of the noise. Objectives: This study has focused on the sequence filters which are selected ...
متن کاملImproved Adaptive Median Filter for Denoising Ultrasound Images
This paper presents a fast and easy method to implement denoising of ultrasound images. One of the very important tasks in the field of image processing is the removal of noise from an image. Noise may arise in the process of image acquisition, its transmission and also in the reproduction of an image. There are several approaches regarding the task of denoising, depending on the nature of the ...
متن کاملAnalysis of Ultrasound Image Denoising using Different Type of filter
This paper proposes an efficient analysis of Ultrasound Image Denoising using different type of filtering methods. The search for efficient image denoising methods is still a valid challenge at the crossing of functional analysis and statistics. Image denoising has become an essential exercise in medical imaging especially the ultrasound image. This paper proposes a medical image denoising algo...
متن کاملA Novel Approach for Despeckling of Ultrasound Images
Ultrasound imaging is a widely used medical imaging modality. But the major issue with ultrasound images is the presence of speckle noise, which is an inherent limitation of ultrasound images. This research work focuses on speckle noise reduction in ultrasound images. Various predefined techniques for despeckling are studied thoroughly and a novel approach is proposed. In addition, comparison o...
متن کاملDenoising Of Intravascular Ultrasound Images: A Comparative Study
The major objective of the image Enhancement techniques is to emphasize & sharpen the features of images for better display & investigation. Medical images are affected by the Mixed Noise, which is the combination of Speckle & Gaussian Noise. Mixed Noise is an inherent property of Intravascular Ultrasound Imaging (IVUS) & it is generally tends to deteriorate the image quality, thereby reducing ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- SpringerPlus
دوره 4 شماره
صفحات -
تاریخ انتشار 2015