Cup Anteversion/tilt Effects on Dislocation Propensity for Small-head-size Total Hip Replacements

نویسندگان

  • M. E. Nadzadi
  • D. R. Pedersen
  • J. J. Callaghan
چکیده

Malposition of the acetabular component is a leading cause of dislocation in total hip arthroplasty (Woo, 1982). The two most influential surgeon-controlled variables are thought to be abduction (tilt) and anteversion of the cup. Empirically, while 30-50° of tilt and 5-25° of anteversion is felt to be a “safe-zone” (Morrey, 1992), dislocation nevertheless remains a disturbingly frequent occurrence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cup Abduction/anteversion Effects on Dislocation Propensity for Small-head-size Thr

INTRODUCTION Malposition of the acetabular component is recognized as a leading cause of dislocation in total hip arthroplasty [4]. Intraoperatively, the most influential surgeon-controlled variables are abduction (tilt) and anteversion (AV) of the cup. Empirically, while 30-50° of tilt and 5-25° of AV is felt to be a “safe-zone” [2], dislocation nevertheless remains a disturbingly frequent occ...

متن کامل

Correcting for Pelvic Posture Influence on Cup Anteversion Measurements

INTRODUCTION Malposition of the acetabular component is a risk factor for postoperative dislocation after total hip arthroplasty (THA)[1]. Current radiographic techniques for assessing cup anteversion have been developed, but they have limitations[2]. The purpose of this study is to investigate the effect of and reduce the error caused by various pelvis postures on cup anteversion measurement. ...

متن کامل

Component positions affect in vivo stability of Total Hip Arthroplasty

INTRODUCTION: Dislocation continues to be a common complication of total hip arthroplasty (THA), affecting 2% to 11% of primary cases. Many factors affect the prevalence of dislocation after THA, including soft tissue laxity, surgical approach, component position, patient factors, and component designs [1,2]. Many in vitro studies have reported the range of motion (ROM) of the hip, impingement,...

متن کامل

Range of Movement for Impingement and Dislocation Avoidance in Total Hip Replacement Predicted by Finite Element Model

Dislocation is a serious complication in total hip replacement (THR). An inadequate range of movement (ROM) can lead to impingement of the prosthesis neck on the acetabular cup; furthermore, the initiation of subluxation and dislocation may occur. The objective of this study was to generate a parametric three-dimensional finite element (FE) model capable of predicting the dislocation stability ...

متن کامل

Is the transverse acetabular ligament a reliable cup orientation guide?

BACKGROUND AND PURPOSE It is controversial whether the transverse acetabular ligament (TAL) is a reliable guide for determining the cup orientation during total hip arthroplasty (THA). We investigated the variations in TAL anatomy and the TAL-guided cup orientation. METHODS 80 hips with osteoarthritis secondary to hip dysplasia (OA) and 80 hips with osteonecrosis of the femoral head (ON) were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000