Internal dosimetry verification and validation database.

نویسندگان

  • G Miller
  • L Bertelli
  • T Little
  • R A Guilmette
چکیده

Simulated-data internal dosimetry cases for use in intercomparison exercises or as a software verification and validation tool have been published on the internet (www.lanl.gov/bayesian/software Bayesian software package II). A user may validate their internal dosimetry code or method using this simulated bioassay data. Or, the user may choose to try out the Los Alamos National Laboratory codes ID and UF, which are also supplied. A Poisson-lognormal model of data uncertainty is assumed. A collection of different possible models for each nuclide (e.g. solubility types and particle sizes) are used. For example, for 238Pu, 14 different biokinetic models or types (8 inhalation, 4 wound and 2 ingestion) are assumed. Simulated data are generated for all the assumed biokinetic models, both for incidents, where the time of intake is known, and for non-incidents, where it is not. For the dose calculations, the route of intake, but not the biokinetic model, is considered to be known. The object is to correctly calculate the known true dose from simulated data covering a period of time. A 'correct' result has been defined in two ways: (1) that the credible limits of the calculated dose include the correct dose and (2) that the calculated dose is within a factor of 2 of the correct dose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms

BACKGROUND To date, the estimated radiation-absorbed dose to organs and tissues in patients undergoing diagnostic examinations in nuclear medicine is derived via calculations based on models of the human body and the biokinetic behaviour of the radiopharmaceutical. An internal dosimetry computer program, IDAC-Dose2.1, was developed based on the International Commission on Radiological Protectio...

متن کامل

Whole body MR-PET: a new internal dosimetry method for radiation transport calculation from biokinetic model data

Institute of Nuclear Sciences Applied to Health (ICNAS), University of Coimbra, Portugal In order to ensure the safe usage of new radiopharmaceuticals in Positron Emission Tomography (PET), it is necessary to quantify the doses delivered to the organs and tissues within the patients’ bodies. A framework that allows estimating the dose delivered by PET has been established by the MIRD Committee ...

متن کامل

Assessment of a 2D EPID-based Dosimetry Algorithm for Pre-treatment and In-vivo Midplane Dose Verification

Introduction: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans both pretreatment and in-vivo. The aim of this study was to test a 2D EPID-based dosimetry algorithm for dose verification of some plans inside a homogenous and anthropomorphic phantom and in-vivo, as well. Materials and Methods: </strong...

متن کامل

A Trust Based Probabilistic Method for Efficient Correctness Verification in Database Outsourcing

Correctness verification of query results is a significant challenge in database outsourcing. Most of the proposed approaches impose high overhead, which makes them impractical in real scenarios. Probabilistic approaches are proposed in order to reduce the computation overhead pertaining to the verification process. In this paper, we use the notion of trust as the basis of our probabilistic app...

متن کامل

Three-dimensional gel dosimetry for dose volume histogram verification in compensator-based IMRT

Background: Some tissues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calculation in order to achieve an accurate dose delivery. Dose verification in complex radiation therapy techniques, such as intensity‐modulated radiation therapy (IMRT) calls for volumetric, tissue equivalent and energy independent dosimeter. The purpose of this...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 127 1-4  شماره 

صفحات  -

تاریخ انتشار 2007