Margin estimation and disturbances of irradiation field in layer-stacking carbon-ion beams for respiratory moving targets

نویسندگان

  • Shinya Tajiri
  • Mutsumi Tashiro
  • Tomohiro Mizukami
  • Chihiro Tsukishima
  • Masami Torikoshi
  • Tatsuaki Kanai
چکیده

Carbon-ion therapy by layer-stacking irradiation for static targets has been practised in clinical treatments. In order to apply this technique to a moving target, disturbances of carbon-ion dose distributions due to respiratory motion have been studied based on the measurement using a respiratory motion phantom, and the margin estimation given by the square root of the summation Internal margin2+Setup margin2 has been assessed. We assessed the volume in which the variation in the ratio of the dose for a target moving due to respiration relative to the dose for a static target was within 5%. The margins were insufficient for use with layer-stacking irradiation of a moving target, and an additional margin was required. The lateral movement of a target converts to the range variation, as the thickness of the range compensator changes with the movement of the target. Although the additional margin changes according to the shape of the ridge filter, dose uniformity of 5% can be achieved for a spherical target 93 mm in diameter when the upward range variation is limited to 5 mm and the additional margin of 2.5 mm is applied in case of our ridge filter. Dose uniformity in a clinical target largely depends on the shape of the mini-peak as well as on the bolus shape. We have shown the relationship between range variation and dose uniformity. In actual therapy, the upper limit of target movement should be considered by assessing the bolus shape.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo computation of dose deposited by carbon ions in radiation therapy

Background: High-velocity carbon ion beams represent the most advanced tool for radiotherapy of deep-seated tumors. Currently, the superiority of carbon ion therapy is more prominent on lung cancer or hepatomas. Materials and Methods: The data for lateral straggling and projected range of monoenergetic 290 MeV/u (3.48 GeV) carbon ions in muscle tissue were obtained from the stopping and range o...

متن کامل

Robustness of Beam Tracking for Moving Tumors

Scanned carbon ion radiotherapy beams provide highly conformal dose distributions for stationary tumors and excellent sparing of nearby normal tissues due to the sharp energy-loss maximum (Bragg peak) near the end of the particle range and minimal lateral Coulomb scattering. For moving targets (e.g., respiratory motion) treatment delivery with scanned ion beams becomes considerably more complex...

متن کامل

Robustness of target dose coverage to motion uncertainties for scanned carbon ion beam tracking therapy of moving tumors.

Beam tracking with scanned carbon ion radiotherapy achieves highly conformal target dose by steering carbon pencil beams to follow moving tumors using real-time magnetic deflection and range modulation. The purpose of this study was to evaluate the robustness of target dose coverage from beam tracking in light of positional uncertainties of moving targets and beams. To accomplish this, we simul...

متن کامل

Fixed-point FPGA Implementation of a Kalman Filter for Range and Velocity Estimation of Moving Targets

Tracking filters are extensively used within object tracking systems in order to provide consecutive smooth estimations of position and velocity of the object with minimum error. Namely, Kalman filter and its numerous variants are widely known as simple yet effective linear tracking filters in many diverse applications. In this paper, an effective method is proposed for designing and implementa...

متن کامل

Irradiation System for HIMAC.

Clinical trials of carbon radiotherapy started at HIMAC in 1994 using three treatment rooms and four beam ports, two horizontal and two vertical. The broad beam method was adopted to make a three-dimensionally uniform field at an isocenter. A spot beam extracted from an accelerator was laterally spread out by using a pair of wobbler magnets and a scatterer. A bar ridge filter modulated the beam...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 58  شماره 

صفحات  -

تاریخ انتشار 2017