Failure of a Carbon Fiber–Reinforced Polymer Implant Used for Transforaminal Lumbar Interbody Fusion

نویسندگان

  • Zeeshan Sardar
  • Peter Jarzem
چکیده

Lumbar interbody fusion is a common procedure owing to the high prevalence of degenerative spinal disorders. During such procedures, carbon fiber-reinforced polymer (CFRP) cages are frequently utilized to fill the void created between adjacent vertebral bodies, to provide mechanical stability, and to carry graft material. Failure of such implants can lead to significant morbidity. We discuss the possible causes leading to the failure of a CFRP cage in a patient with rheumatoid arthritis. Review of a 49-year-old woman who underwent revision anterior lumbar interbody fusion 2 years after posterior instrumentation and transforaminal lumbar interbody fusion at L4-L5 and L5-S1. The patient developed pseudarthrosis at the two previously fused levels with failure of the posterior instrumentation. Revision surgery reveled failure with fragmentation of the CFRP cage at the L5-S1 level. CFRP implants can break if mechanical instability or nonunion occurs in the spinal segments, thus emphasizing the need for optimizing medical management and meticulous surgical technique in achieving stability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Instrumented transforaminal lumbar interbody fusion in surgical treatment of recurrent disc herniation

  Background :The incidence of recurrence in patients undergoing primary discectomy due to lumbar disc herniation (LDH), is regularly reported as 5-15%. In this study we aimed to evaluate surgical outcome of instrumented transforaminal lumbar interbody fusion (TLIF) in the patients suffering from recurrent LDH.   Methods : We retrospectively studied 51 patients (30 female, 21 male) from August ...

متن کامل

Successful salvage surgery for failed transforaminal lumbosacral interbody fusion using the anterior transperitoneal approach

Transforaminal lumbar interbody fusion (TLIF) is a popular posterior spinal fusion technique, but sometimes require salvage surgery when implant failure occurs, which involves possible neural damage due to postoperative adhesion. The current report deals with successful anterior transperitoneal salvage surgery for failed L5-S TLIF with less neural invasiveness.

متن کامل

Does TLIF aggravate adjacent segmental degeneration more adversely than ALIF? A finite element study.

AIM To determine whether transforaminal lumbar interbody fusion aggravate adjacent segmental degeneration more adversely than anterior lumbar interbody fusion. MATERIAL AND METHODS A normal finite element model, an anterior lumbar interbody fusion model and a transforaminal lumbar interbody fusion model of L3-5 were developed. 800 N compressive loading plus 10 Nm moments simulating flexion, e...

متن کامل

Transforaminal lumbar interbody fusion for failed Graf ligamentoplasty: a report of two cases.

We report 2 cases of transforaminal lumbar interbody fusion for failed Graf ligamentoplasty. Both patients had residual or recurrent low back pain and leg pain after Graf ligamentoplasty, caused by lumbar segmental instability or narrowing of their intervertebral foramens. The pain improved markedly after the revision surgery. We recommend transforaminal lumbar interbody fusion for failed Graf ...