Looking beyond endotoxin: a comparative study of pyrogen retention by ultrafilters used for the preparation of sterile dialyis fluid
نویسندگان
چکیده
Sterile single-use ultrafilters are used in dialysis for the preparation of the substitution fluid given to patients undergoing dialysis treatments with high convective fluid removal. The retention of pyrogenic agents by the ultrafilters is crucial to avoiding inflammatory responses. The performance of a new single-use ultrafilter (NUF) with a positively charged flat sheet membrane of relatively small membrane area and large pore size was compared to a reference ultrafilter (RUF) with a hollow fiber membrane. Filter performance was tested with various pyrogen-contaminated dialysis fluids by direct pyrogen quantification and by measuring inflammatory responses in cell-based bioassays. The NUF completely retained oligodeoxynucleotides (ODN), whereas the RUF was fully permeable. Both filters tended to decrease biological activity of DNA in filtered bacterial lysates. The NUF reduced lipopolysaccharides (LPS) and LPS-induced biological activity by 100%, whereas the RUF produced filtrates with low but detectable levels of LPS in most cases. Peptidoglycans (PGN) were fully retained both by the NUF and the RUF. The new ultrafilter retained biologically active ODN, which has not yet been described for any other device used in dialysis, and it showed better or equal retention of LPS and PGN even with a smaller membrane surface and larger pore size.
منابع مشابه
On-line preparation of solutions for dialysis: practical aspects versus safety and regulations.
On-line preparation, i.e., continuous mixing and immediate use, was introduced for dialysis fluid in 1964, and it contributed significantly to the expansion of dialysis therapy through simplified handling, improved microbiology, and enhanced efficiency. On-line prepared replacement solution for hemofiltration was shown to be clinically safe as early as 1978, but the implementation was delayed f...
متن کاملEndotoxin Contamination of Large Volume Parenterals as Detected by Limulus Amebocyte Lysate as an Alternative to Rabbit Pyrogen Test
The possibility of replacing the rabbit pyrogen test by the Limulus Amebocyte lysate (LAL) test, as a final release test for Large Volume Parenterals (LVPs) was investigated. The sensitivity and specificity of the LAL test and rabbit pyrogen assay were studied by means of artificially contaminated parenterals. Various LVPs (mostly containing electrolytes) were spiked with 0.5 and 5 EUlml o...
متن کاملPreparation of human serum albumin microspheres (MSA) kit for lung imaging in Iran [Persian]
Radiolabeled Microspheres of human serum albumin (MSA) is of great importance in the analysis of regional lung perfusion. Preparation of MSA kit has been installed in our Division recently is carried out in two stages: 1. Production of albumin sphere particles with suitable sizes by using the spinning disk technique. 2. Formulation of MSA as a radiopharmacutical kit. So it can be labelled...
متن کاملEffect of administrated activity, admission number and TSH level on radiation retention curve of patients taking iodine-131 therapy for differentiated thyroid carcinoma: Looking beyond established regulations
Introduction: Retention of I-131 in the body of patients with differentiated thyroid carcinoma (DTC) has a direct effect on therapeutic outcome of radioiodine therapy. There are several factors that may influence retention time of radioiodine in the body of these patients. In this study we are going to assess effects of administered radioiodine activity, serum thyroid stimulati...
متن کاملPreoperative Sterilization Preparation of the Shoulder: A Comparative Study Evaluating Gauze Sponge and Commercially Available Applicator Prep Stick
Background: Surgical site infection (SSI) remains a concern in shoulder surgery, especially during arthroplasty. Whilemany studies have explored the characteristics and efficacy of different sterilizing solutions, no study has evaluated themethod of application. The purpose of this study was to compare two popular pre-surgical preparatory applications (two4 x 4 cm gauze sponges and applicator s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 4 شماره
صفحات -