Robustly passivated, gold nanoaperture arrays for single-molecule fluorescence microscopy.

نویسندگان

  • Colin D Kinz-Thompson
  • Matteo Palma
  • Dileep K Pulukkunat
  • Daniel Chenet
  • James Hone
  • Shalom J Wind
  • Ruben L Gonzalez
چکیده

The optical confinement generated by metal-based nanoapertures fabricated on a silica substrate has recently enabled single-molecule fluorescence measurements to be performed at physiologically relevant background concentrations of fluorophore-labeled biomolecules. Nonspecific adsorption of fluorophore-labeled biomolecules to the metallic cladding and silica bottoms of nanoapertures, however, remains a critical limitation. To overcome this limitation, we have developed a selective functionalization chemistry whereby the metallic cladding of gold nanoaperture arrays is passivated with methoxy-terminated, thiol-derivatized polyethylene glycol (PEG), and the silica bottoms of those arrays are functionalized with a binary mixture of methoxy- and biotin-terminated, silane-derivatized PEG. This functionalization scheme enables biotinylated target biomolecules to be selectively tethered to the silica nanoaperture bottoms via biotin-streptavidin interactions and reduces the nonspecific adsorption of fluorophore-labeled ligand biomolecules. This, in turn, enables the observation of ligand biomolecules binding to their target biomolecules even under greater than 1 μM background concentrations of ligand biomolecules, thereby rendering previously impracticable biological systems accessible to single-molecule fluorescence investigations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Label-free free-solution nanoaperture optical tweezers for single molecule protein studies.

Nanoaperture optical tweezers are emerging as useful label-free, free-solution tools for the detection and identification of biological molecules and their interactions at the single molecule level. Nanoaperture optical tweezers provide a low-cost, scalable, straight-forward, high-speed and highly sensitive (SNR ∼ 33) platform to observe real-time dynamics and to quantify binding kinetics of pr...

متن کامل

Crucial role of the adhesion layer on the plasmonic fluorescence enhancement.

A nanoscale layer of chromium or titanium is commonly used in plasmonic nanoantennas to firmly adhere a gold film to a glass substrate, yet the influence of this layer on the antenna performance is often ignored. As a result, the need for the use of potentially better materials is not widely recognized. Using a single aperture milled in a gold film with 120 nm diameter as a nanobench for these ...

متن کامل

Investigation on the plasmon Talbot effect of finite-sized periodic arrays of metallic nanoapertures

We present an in-depth and systematical investigation on the plasmon Talbot effect of finite-sized two-dimensional (2D) periodic metallic nanoaperture arrays. The nanoaperture shapes, fill factor, lattice distribution, array size, film thickness, material property and polarization state of the incident light are considered, and the inherent influencing rules are summarized via the three-dimensi...

متن کامل

Interaction of a conjugated polyaromatic molecule with a single dangling bond quantum dot on a hydrogenated semiconductor.

Controlling the strength of the coupling between organic molecules and single atoms provides a powerful tool for tuning electronic properties of single-molecule devices. Here, using scanning tunneling microscopy and spectroscopy (STM/STS) supported by theoretical modeling, we study the interaction of a planar organic molecule (trinaphthylene) with a hydrogen-passivated Ge(001):H substrate and a...

متن کامل

Accurate single molecule FRET efficiency determination for surface immobilized DNA using maximum likelihood calculated lifetimes.

Single molecule fluorescent lifetime trajectories of surface immobilized double-stranded DNA coupled with a tetramethylrhodmaine and Cy5 FRET pair were directly measured using time-tagged single-photon counting and scanning confocal microscopy. A modified maximum likelihood estimator (MLE) was developed to compensate for localized background fluorescence and instrument response. With this algor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • ACS nano

دوره 7 9  شماره 

صفحات  -

تاریخ انتشار 2013