Biomechanical Comparison of Fracture Risk Created by 2 Different Clavicle Tunnel Preparations for Coracoclavicular Ligament Reconstruction
نویسندگان
چکیده
BACKGROUND An anatomic reconstruction of coracoclavicular (CC) ligaments typically requires drilling tunnels in the clavicle. An increase in fracture complications has been associated with graft tunnel position. A method of drilling clavicle tunnels that would better re-create anatomic function of the CC ligaments without increasing fracture risk would be an improvement. PURPOSE To evaluate the feasibility of a novel single anterior-to-posterior tunnel technique and compare the biomechanical properties to the 2-tunnel technique in CC ligament reconstruction. The hypothesis was that the single tunnel will yield similar loads to failure as the 2-tunnel technique and better reproduce the native anatomy of the conoid and trapezoid ligaments. STUDY DESIGN Controlled laboratory study. METHODS Eight fresh-frozen matched pairs of human clavicles underwent testing. In 1 specimen of the matched pair, 2 bone tunnels were created as previously described. In the other, a single tunnel was placed obliquely from anterior to posterior. The relative position of the tunnels in relation to the conoid tuberosity was recorded. Specimens were tested on a materials testing machine. The ultimate load to failure, linear stiffness, distance of the conoid tuberosity to the conoid tunnel exit point, and mode of failure were recorded. RESULTS The ultimate load to failure in the single-tunnel group and the 2-tunnel group was 457.2 ± 139.8 and 488.8 ± 170.6, respectively. There was no significant difference (P = .5). The linear stiffness in the single-tunnel group and the 2-tunnel group was 94.6 ± 31.3 and 79.8 ± 33.5, respectively. There was no significant difference (P = .2). The 2-tunnel group had a significantly longer average maximum distance from the conoid tuberosity to the conoid tunnel exit point than the single-tunnel group (6.0 ± 2.1 vs 0.8 ± 1.9 mm; P = .05). The single-tunnel group was consistently more anatomic with regard to its relationship to the conoid tuberosity than the 2-tunnel group. CONCLUSION The single anterior-to-posterior clavicle tunnel had similar biomechanical properties to the 2-tunnel technique. However, the single-tunnel technique better reproduced the anatomic footprint of the conoid ligament. Utilizing this single-tunnel technique may yield an anatomic advantage that may also reduce the rate of complications caused by posterior wall blowout. CLINICAL RELEVANCE Acromioclavicular joint injuries are common in collision sports. Surgical management is often indicated to reconstruct the joint. This study assesses the feasibility of a novel surgical approach.
منابع مشابه
Clavicle Fracture after Coracoclavicular Ligament Reconstruction: A Biomechanical and Finite Element Evaluation of Clavicle Fracture Risk
This open‐access article is published and distributed under the Creative Commons Attribution ‐ NonCommercial ‐ No Derivatives License (http://creativecommons.org/licenses/by‐nc‐nd/3.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article w...
متن کاملBiomechanical Consequences of Coracoclavicular Reconstruction Techniques on Clavicle Strength
BACKGROUND Lateral clavicle fractures have been reported after coracoclavicular (CC) ligament reconstructions with bone tunnels through the clavicle. PURPOSE To biomechanically compare clavicle strength following 2 common CC reconstruction techniques with different bone tunnel diameters. STUDY DESIGN Controlled laboratory study. METHODS Testing was performed on 2 groups of matched-pair ca...
متن کاملBiomechanical Evaluation of Hole Diameter for Coracoclavicular Ligament Reconstruction on Coracoid Strength
INTRODUCTION: Many acromioclavicular joint injuries involve damage to the coracoclavicular (CC) ligaments. Some current techniques for CC ligament reconstruction utilize a hole drilled in the coracoid process for placement of a fixation device. Such a hole may increase the probability of coracoid fracture; however, there are no studies in literature that have attempted to evaluate the effects o...
متن کاملBiomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery
Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...
متن کاملCoracoid Process Avulsion Fracture at the Coracoclavicular Ligament Attachment Site in an Osteoporotic Patient with Acromioclavicular Joint Dislocation
Coracoid fractures are uncommon, mostly occur at the base or neck of the coracoid process (CP), and typically present with ipsilateral acromioclavicular joint (ACJ) dislocation. However, CP avulsion fractures at the coracoclavicular ligament (CCL) attachment with ACJ dislocation have not been previously reported. A 59-year-old woman receiving glucocorticoid treatment fell from bed and complaine...
متن کامل