ExPRESS Mini-Shunt as a Treatment Alternative for Medically Uncontrolled Steroid-Induced Glaucoma in a Pediatric Patient
نویسندگان
چکیده
This case report illustrates the use of ExPRESS mini-shunt in a pediatric glaucoma patient. We describe the management of steroid-induced glaucoma with ExPRESS mini-shunt in a 9-year-old boy with allergic keratoconjunctivitis. The intraocular pressure of both of his eyes was uncontrolled with medical and laser treatment. Both eyes were treated with ExPRESS mini-shunt and mitomycin-C. Transient overfiltration with postoperative hypotony occurred in both eyes and resolved after 2 weeks. One year postoperatively, intraocular pressure was maintained below 21 mm Hg without medication in 1 eye. Bleb needling with mitomycin-C was done to maintain filtration. The fellow eye received cataract extraction but developed bleb failure a few months afterwards. The intraocular pressure was controlled medically. To conclude, ExPRESS mini-shunt is a new surgical option in selected patients. Bleb failure developed after cataract extraction. Postoperative inflammation should be minimized. Patient selection, such as those with stable ocular condition, is important to increase surgical success.
منابع مشابه
Glaucoma Surgery in Pregnancy: A Case Series and Literature Review
AbstractGlaucoma management in pregnant patients is a real challenge, especially when the glaucoma is not controlled with medications. We report the results of 6 incisional glaucoma surgeries for the management of medically uncontrolled glaucoma patients during pregnancy. This retrospective, case series was conducted on the 6 eyes of 3pregnant patients with uncontrolled glaucoma using maximum t...
متن کاملInterference of Descemet's Membrane with Aqueous Humor Drainage via an ExPRESS Mini Shunt
PURPOSE To describe a case in which Descemet's membrane interfered with aqueous humor drainage through an ExPRESS mini shunt. This problem was successfully solved by Nd:YAG laser membranotomy. CASE REPORT A 70-year-old male, diagnosed with corticosteroid-induced glaucoma in his right eye, presented to our hospital. Topical betamethasone treatment was discontinued, and the patient was treated ...
متن کاملSurgical Outcomes of Ahmed or Baerveldt Tube Shunt Implantation for medically Uncontrolled Traumatic Glaucoma
AIM To describe postoperative surgical success of either Ahmed or Baerveldt tube shunt implantation for eyes with medically uncontrolled traumatic glaucoma. MATERIALS AND METHODS A review was carried out to identify patients with traumatic glaucoma that required tube shunt implantation between 2009 and 2015 at Rutgers University in Newark, New Jersey, USA. Seventeen eyes from 17 patients met ...
متن کاملLong-term Follow-up of a Case of Gold Shunt Surgery for Refractory Silicone Oil–induced Glaucoma
PURPOSE To report the first case of gold shunt surgery for treatment of silicone oil-induced refractory glaucoma in a tertiary care academic center, with 5-year follow-up. DESIGN The study design is a case report. PARTICIPANTS The participant was a patient who underwent gold shunt surgery. METHODS Institutional Research Ethics Board approval for the study was obtained. A diabetic patient ...
متن کاملProspective Randomized Study Comparing Combined Phaco-ExPress and Phacotrabeculectomy in Open Angle Glaucoma Treatment: 12-Month Follow-Up
Purpose of the Study. To compare the efficacy and safety of phacotrabeculectomy (P-Trab) and phacoemulsification with the ExPress (P-ExPress) mini glaucoma shunt implantation. Study Plan. Prospective randomized study. Material and Methods. 85 eyes with cataract and unregulated open angle glaucoma. There were 46 eyes in the P-ExPress and 39 the P-Trab group. Intraocular pressure (IOP), the numbe...
متن کامل