Use of laser nephelometry in the measurement of serum proteins.
نویسندگان
چکیده
Measurement of immunoglobulins (Ig) and of complement component C3 in human serum by automated and manual nephelometric techniques is tedious, and the effective linear range is too narrow. We describe a laser nephelometer/reagent system for measuring serum proteins by the use of forward light scatter (which enhances the ratio of reaction/blank), electronic blank subtraction, laser light (632 nm), and electronic signal selection. We report data establishing the range of linearity for immunoglobulins IgG, IgA, IgM, and complement C3 with this system, and correlations with results by a radial immunodiffusion. We also compared an electroimmunodiffusion system for quantitation of albumin and IgG in cerebrospinal fluid to our technique. The nephelometric system described provides a rapid, accurate, precise, and objective way to measure immunoglobulins and C3.
منابع مشابه
Laser nephelometric measurement of seven serum proteins compared with radial immunodiffusion.
Quantification of immunoglobulins IgG, IgA, IgM, C3 complement, siderophilin, alpha 2-macroglobulin and haptoglobin in serum by a Behring laser nephelometer coupled with a date processing apparatus was compared with values obtained by the radial immunodiffusion method of Mancini. The precision was not improved by the use of the laser nephelometer as compared to Mancini radial immunodiffusion, b...
متن کاملComparison of radial immunodiffusion and laser nephelometry for quantitating some serum proteins.
After quantitating immunoglobulins G, A, and M and complement C3c and C4 in serum by using a laser nephelometer coupled with a data processor, I compared these results with values obtained by an early-readout radial immunodiffusion method. Day-to-day precision was better for nephelometry than for radial immunodiffusion for all proteins analyzed. The average coefficient of variation was 6.0% for...
متن کاملRapid determination of proteins in serum and cerebrospinal fluid by laser-nephelometry.
The Laser-nephelometric technique is characterized by its easy handling, accuracy, good reproducibility and especially by the short time in which reliable results are available. A very good correlation was found between the results obtained by the electroimmunoassay and those obtained by Laser-nephelometry. In both techniques alpha2-macroglobulin is the largest serum protein that can be determi...
متن کاملComparison of immunoglobulin determinations in pathological sera by radial immunodiffusion and laser nephelometry.
Immunoglobulins G, A, and M were measured by radial immunodiffusion and by laser nephelometry in sera from 33 patients and in a preparation of purified colostral IgA. In general the results agreed for the two methods, with some exceptions attributed to the physicochemical characteristics of the immunoglobulins assayed: low-molecular-weight (monomeric) IgM gives falsely high values and IgA prote...
متن کاملA distinct serum protein pattern in patients with paranoid schizophrenia
Introduction: Schizophrenia is a chronic mental illness, whose aetiology is still unclear; therefore, information about differences in serum protein patterns may improve the understanding of the pathophysiology of schizophrenia. The goal of this study was to use the proteomic approach to identify altered protein levels in the serum samples from patients with schizophrenia. Methods: Blood wa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 22 9 شماره
صفحات -
تاریخ انتشار 1976