Force Relaxation Characteristics of Medium Force Orthodontic Latex Elastics: A Pilot Study

نویسندگان

  • Daniel J. Fernandes
  • Gisele M. Abrahão
  • Carlos N. Elias
  • Alvaro M. Mendes
چکیده

To evaluate force extension relaxation of different brands and diameters of latex elastics subjected to static tensile testing under an apparatus designed to simulate oral environments, sample sizes of 5 elastics from American Orthodontics (AO), Tp, and Morelli Orthodontics (Mo) of equivalent medium force, (3/16, 1/4, and 5/16 inch size) were tested. The forces were read after 1-, 3-, 6-, 12- and 24-hour periods in Emic testing machine with 30 mm/min cross-head speed and load cell of 20 N. Two-way ANOVA and Bonferroni tests were used to identify statistical significance. There were statistically differences among different manufacturers at all observation intervals (P < 0.0001). The relationships among loads at 24-hour time period were as follows: Morelli>AO>Tp for 3/16, 1/4, and 5/16 elastics. The force decay pattern showed a notable drop-off of forces until 3 hours, a slight increase in some groups from 3-6 hours and a more homogeneous force pattern over 6-24 hours.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Elasticity in Elastics-An in-vitro study.

BACKGROUND Orthodontic tooth movement results from application of forces to teeth. Elastics in orthodontics have been used both intra-orally and extra- orally to a great effect. Their use, combined with good patient co-operation provides the clinician with the ability to correct both anteroposterior and vertical discrepancies. Force decay over a period of time is a major problem in the clinical...

متن کامل

In vitro study of force decay of latex and non-latex orthodontic elastics.

The aim of this study was to evaluate the force decay of two brands of orthodontic elastics, both offering latex and non-latex products. Samples were subjected to continuous stretching, measuring force at 5 seconds, 8 hours, and 24 hours in both dry and wet conditions. Five hundred samples were used, GAC® and Lancer® 0.25 inch and 4 oz, divided into testing sample sizes of n = 25 per group. For...

متن کامل

Latex and non-latex orthodontic elastic force loss due to cyclic temperature.

UNLABELLED The purpose of this study was to compare the force loss of 1/4 inch (6.35mm) 3.5oz (99g) medium latex elastics from Ormco Corp. to non-latex elastics from ClassOne Orthodontics and Phoenix after being cycled between different temperatures. Elastics were stretched to 1.57 inches (40mm) on jigs and cycled in water baths for 4 minutes at 5 degrees C and 37 degrees C, 21 degrees C and 37...

متن کامل

An In-vitro Comparison of Force Loss of Orthodontic Non-Latex Elastics

OBJECTIVE The amount and consistency of the applied forces to the tooth are important factors in tooth movements; therefore, the aim of this study was to compare the initial force and the force loss of three brands of elastics in 24 hours. MATERIALS AND METHODS In this in-vitro study sixty non-latex elastics (3/16 medium) from three companies (Forestadent, Dentaurum and Ortho Technology) were...

متن کامل

Cytotoxicity of Intermaxillary Orthodontic Elastics of Different Colors: an in Vitro Study

OBJECTIVES Natural latex does not fall into the category of materials known to be entirely inoffensive. The purpose of this in vitro study was to test the hypothesis that there is no difference in the cytotoxicity between elastics of different colors and those from different manufacturers. MATERIAL AND METHODS Different latex intraoral elastics of different colors (5/16 = 7.9 mm, mean load) w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2011  شماره 

صفحات  -

تاریخ انتشار 2011