Evaluation of standard and active compression-decompression CPR in an acute human model of ventricular fibrillation.

نویسندگان

  • J J Shultz
  • P Coffeen
  • M Sweeney
  • B Detloff
  • C Kehler
  • E Pineda
  • P Yakshe
  • S W Adler
  • M Chang
  • K G Lurie
چکیده

BACKGROUND The mechanisms that underlie cardiopulmonary resuscitation (CPR) in humans remain controversial and difficult to study. This report describes a new human model to evaluate CPR during the first 1 to 2 minutes after the onset of ventricular fibrillation (VF). With this model, standard CPR was compared with active compression-decompression (ACD) CPR, a method that uses a handheld suction device to actively compress and actively decompress the chest. METHODS AND RESULTS During routine inductions of VF as part of a transvenous lead cardioverter/defibrillator implantation procedure, CPR was performed in 21 patients if the first defibrillation shock failed and until a successful rescue shock was delivered. Compressions during CPR were performed according to American Heart Association guidelines. For ACD CPR, decompression was performed with up to -30 lbs. Radial arterial and right atrial pressures were measured in all patients. Esophageal pressures, intratracheal pressures, or minute ventilation was measured in the last 13 patients. Application of both CPR techniques increased arterial and right atrial pressures. The mean coronary perfusion pressure was increased throughout the entire CPR cycle with ACD CPR (compression, 21.5 +/- 9.0 mm Hg; decompression, 21.9 +/- 8.7 mm Hg) compared with standard CPR (compression, 17.9 +/- 8.2 mm Hg; decompression, 18.5 +/- 6.9 mm Hg; P < .02 and P < .02, respectively). Ventilation per compression-decompression cycle was 97.3 +/- 65.6 mL with standard CPR and 168.4 +/- 68.6 mL with ACD CPR (n = 7, P < .001). Negative inspiratory pressure was -0.8 +/- 4.8 mm Hg with standard CPR and -11.4 +/- 6.3 mm Hg with ACD CPR (n = 6, P < .04). CONCLUSIONS Patients undergoing multiple inductions of VF during cardioverter/defibrillator implantation with transvenous leads provide a well-controlled and reproducible model to study the mechanisms of CPR. Using this model, ACD CPR significantly increased arterial blood pressure, coronary perfusion pressure, minute ventilation, and negative inspiratory pressure compared with standard CPR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acute Human Model of Ventricular Fibrillation

Background The mechanisms that underlie cardiopulmonary resuscitation (CPR) in humans remain controversial and difficult to study. This report describes a new human model to evaluate CPR during the first 1 to 2 minutes after the onset of ventricular fibrillation (VF). With this model, standard CPR was compared with active compression-decompression (ACD) CPR, a method that uses a handheld suctio...

متن کامل

Use of an inspiratory impedance threshold valve during cardiopulmonary resuscitation: a progress report.

Building upon studies on the mechanism of active compression-decompression (ACD) cardiopulmonary resuscitation, a new inspiratory impedance threshold valve has been developed to enhance the return of blood to the thorax during the decompression phase of CPR. Use of this device results in a greater negative intrathoracic pressure during chest wall decompression. This leads to improved vital orga...

متن کامل

Active compression-decompression CPR improves vital organ perfusion in a dog model of ventricular fibrillation.

OBJECTIVES This study was designed to assess whether a new method of cardiopulmonary resuscitation (CPR), termed active compression-decompression CPR, or ACD-CPR, improves organ perfusion when compared with standard (S) CPR in a dog model of ventricular fibrillation. BACKGROUND ACD-CPR has recently been shown to improve hemodynamic and respiratory parameters during cardiac arrest when compare...

متن کامل

Effects of active compression-decompression resuscitation on myocardial and cerebral blood flow in pigs.

BACKGROUND This study was designed to assess the effects of a modified cardiopulmonary resuscitation (CPR) technique that consists of both active compression and active decompression of the chest (ACD CPR) versus standard CPR (STD CPR) on myocardial and cerebral blood flow during ventricular fibrillation both before and after epinephrine administration. METHODS AND RESULTS During a 30-second ...

متن کامل

Comparison of standard cardiopulmonary resuscitation versus the combination of active compression-decompression cardiopulmonary resuscitation and an inspiratory impedance threshold device for out-of-hospital cardiac arrest.

BACKGROUND Active compression-decompression (ACD) CPR combined with an inspiratory impedance threshold device (ITD) improves vital organ blood flow during cardiac arrest. This study compared survival rates with ACD+ITD CPR versus standard manual CPR (S-CPR). METHODS AND RESULTS A prospective, controlled trial was performed in Mainz, Germany, in which a 2-tiered emergency response included ear...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 89 2  شماره 

صفحات  -

تاریخ انتشار 1994