Reliability of two goniometric methods of measuring active inversion and eversion range of motion at the ankle

نویسندگان

  • Collette Menadue
  • Jacqueline Raymond
  • Sharon L Kilbreath
  • Kathryn M Refshauge
  • Roger Adams
چکیده

BACKGROUND Active inversion and eversion ankle range of motion (ROM) is widely used to evaluate treatment effect, however the error associated with the available measurement protocols is unknown. This study aimed to establish the reliability of goniometry as used in clinical practice. METHODS 30 subjects (60 ankles) with a wide variety of ankle conditions participated in this study. Three observers, with different skill levels, measured active inversion and eversion ankle ROM three times on each of two days. Measurements were performed with subjects positioned (a) sitting and (b) prone. Intra-class correlation coefficients (ICC[2,1]) were calculated to determine intra- and inter-observer reliability. RESULTS Within session intra-observer reliability ranged from ICC[2,1] 0.82 to 0.96 and between session intra-observer reliability ranged from ICC[2,1] 0.42 to 0.80. Reliability was similar for the sitting and the prone positions, however, between sessions, inversion measurements were more reliable than eversion measurements. Within session inter-observer measurements in sitting were more reliable than in prone and inversion measurements were more reliable than eversion measurements. CONCLUSION Our findings show that ankle inversion and eversion ROM can be measured with high to very high reliability by the same observer within sessions and with low to moderate reliability by different observers within a session. The reliability of measures made by the same observer between sessions varies depending on the direction, being low to moderate for eversion measurements and moderate to high for inversion measurements in both positions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Goniometric reliability in a clinical setting. Subtalar and ankle joint measurements.

Measurements of the subtalar joint neutral (STJN) position and passive range of motion (PROM) of the ankle joint and the subtalar joint (STJ) are often part of a physical therapy evaluation. These measurements may be used in treatment planning, such as in the prescription of specialized shoes or orthoses. Therefore, reliability of these measurements, as they are obtained clinically, must be det...

متن کامل

اثر نوارپیچی بر ثبات پویا و دامنه حرکتی فعال در ورزشکاران زن با و بدون بی ثباتی مزمن مچ پا

Objective: The purpose of this investigation is the study of the effect of ankle taping on dynamic stability and active range of motion in the female athletes with and without chronic ankle instability. Materials & Methods: 22 female athletes participated in this investigation: 12 subjects with chronic ankle instability and 12 healthy subjects. Time to stabilization measured with force plate i...

متن کامل

مقایسه اثر بریس عمل‌کردی و گچ‌گیری کوتاه ساق بر متغیرهای راه رفتن در افراد مبتلا به کشیدگی درجه 2 و 3 مجموعه لیگامانی خارجی مچ پا

People with acute ankle sprains walk slowly and take smaller steps because of having pain, swelling and limited range of motion. While inversion ankle sprains are one of the most frequently occurring injuries among athletes and physically active people, the optimal method of treatment is still controversial. Various treatment plans for the management of acute ankle injuries have bee...

متن کامل

Investigating the Correlation between Range of Motion of Joints with the Time of Running Types in Adolescent Elite Runner Girls Participating in National Competitions in 2018 in Ardabil City: A Descriptive Study

Background and Objectives: The relationship between range of motion of joints with running time is important to achieve athletic success. The aim of this study was investigating the correlation between range of motion of joints with the time of running types in adolescent elite runner girls participating in 2018 national competitions in Ardabil city. Materials and Methods: In this descriptive ...

متن کامل

Test-retest reliability of biodex system 4 pro for isometric ankle-eversion and -inversion measurement.

CONTEXT The lack of knowledge about isometric ankle testing indicates the need for research in this area. OBJECTIVE to assess test-retest reliability and to determine the optimal position for isometric ankle-eversion and -inversion testing. DESIGN Test-retest reliability study. Isometric ankle eversion and inversion were assessed in 3 different dynamometer foot-plate positions: 0°, 7°, and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Musculoskeletal Disorders

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2006