Cyclic voltammetry at micropipet electrodes for the study of ion-transfer kinetics at liquid/liquid interfaces.
نویسندگان
چکیده
Cyclic voltammetry at micropipet electrodes is applied to the kinetic study of ion transfer at liquid/liquid interfaces. Simple and facilitated transfer of an ion that is initially present outside a tapered pipet was simulated by the finite element method, enabling complete analysis of the resulting transient cyclic voltammogram (CV) with a sigmoidal forward wave followed by a peak-shaped reverse wave. Without serious effects of uncompensated ohmic resistance and capacitive current, more parameters can be determined from a transient CV than from the steady-state counterpart obtained with a smaller pipet or at a slower scan rate. A single transient CV under kinetic limitation gives all parameters in a Butler-Volmer-type model, i.e., the formal potential, the transfer coefficient, the standard ion-transfer rate constant, k(0), and the charge of a transferring ion as well as its diffusion coefficients in both phases. Advantages of the transient approach are demonstrated experimentally for reversible, quasi-reversible and irreversible cases. With a multistep transfer mechanism, an irreversible transient CV of facilitated protamine transfer gives an apparent k(0) value of 3.5 x 10(-5) cm/s, which is the smallest k(0) value reported so far. With the largest reliable k(0) value of approximately 1 cm/s reported in the literature, an intrinsic rate of the interfacial ion transfer varies by at least 5 orders of magnitude.
منابع مشابه
Electrocatalytic oxidation of sulfite Ion at the surface carbon ceramic modified electrode with prussian blue
The redox properties of sulfite ion has been examind using cyclic voltammetry in acetonitrile solvent at the surface of gold, pelatin and glassy carbon electrodes. It has bben found tha, sulfite ion exhibits two electron oxidation peak with EC’ mechanism. A novel chemically modified electrode containing Prussian blue complex and multi wall carbon nanotubes (MWCNs) was achieved on the surface of...
متن کاملElectrochemical Behavior and Highly Sensitive Voltammetric Determination of Doxepin in Pharmaceutical Preparations and Blood Serum Using Carbon Ionic Liquid Electrode
In this manuscript, the electrocatalytic oxidation of doxepin (DOX) was studied at a carbon ionic liquid electrode, fabricated using graphite, and the ionic liquid 1-octylpyridinium hexaflourophosphate (OPFP). The surface of the proposed electrode was characterized by scanning electron microscopy. Differential pulse voltammetry was applied as an analytical technique for quantification of sub-mi...
متن کاملNumerical Study of Electro-thermo-convection in a Differentially Heated Cavity Filled with a Dielectric Liquid Subjected to Partial Unipolar Injection
The Coulomb force applied by an electric field on any charge present in a dielectric liquid may cause fluid motion. At high applied electric fields in an insulating liquid, electric charge carriers are created at metallic/liquid interfaces, a process referred to as ion injection, and result from electrochemical reactions. In this article we deals with the problem of electro thermal convection i...
متن کاملElectrochemical Behavior and Highly Sensitive Voltammetric Determination of Doxepin in Pharmaceutical Preparations and Blood Serum Using Carbon Ionic Liquid Electrode
In this manuscript, the electrocatalytic oxidation of doxepin (DOX) was studied at a carbon ionic liquid electrode, fabricated using graphite, and the ionic liquid 1-octylpyridinium hexaflourophosphate (OPFP). The surface of the proposed electrode was characterized by scanning electron microscopy. Differential pulse voltammetry was applied as an analytical technique for quantification of sub-mi...
متن کاملSynergistic Signal Amplification Based on Ionic Liquid-BaTiO3 Nanoparticle Carbon Paste Electrode for Sensitive Voltammetric Determination of Acetaminophen
Monitoring the acetaminophen in biological samples and also in pharmaceutical formulations is important due to the concerns of public health care and drug safety. In this work a carbon paste electrode modified with BaTiO3 nanoparticle (BTO NPs) and room-temperature ionic liquid (IL) (n-hexyl-3-methylimidazolium hexafluoro phosphate) was fabricated. The direct electro-oxidation behavior of aceta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 79 24 شماره
صفحات -
تاریخ انتشار 2007