Differential blast counts obtained by automated blood cell analyzers.

نویسندگان

  • Seungwon Jung
  • Hyojin Chae
  • Jihyang Lim
  • Eun-Jee Oh
  • Yonggoo Kim
  • Yeon-Joon Park
  • Kyungja Han
چکیده

BACKGROUND Automated blood cell analyzers often read leukemic blasts as normal cells. In this study, we evaluated the 5-part differential patterns of blasts using automated analyzers to determine if they can differentiate among blast types. METHODS Blood samples containing 10% or more blasts were collected from patients with acute leukemia (N=175). The 5-part differential count was conducted using DxH 800 (Beckman Coulter, USA) and XE-2100 analyzers (Sysmex Co., Japan), and the results were compared with manual differential counts, which was used as a reference method. RESULTS The DxH 800 reported the 5-part white blood cell differential count in 98.9% of the cases. The XE-2100 provided an invalid automated differential count in 72% of the cases. Both analyzers counted most lymphoblasts as lymphocytes and most myeloblasts as monocytes. In 11 cases, the DxH 800 reported a 5-part differential count without a blast flag. CONCLUSIONS Some automated analyzers are able to recognize and count blasts according to their characteristic cell types. Therefore, complete blood counts obtained automatically can provide valuable data for making provisional decisions regarding the lineage of leukemia cells before further investigation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of automated differential blood cell counts from Abbott Sapphire, Siemens Advia 120, Beckman Coulter DxH 800, and Sysmex XE-2100 in normal and pathologic samples.

Reliable automated blood cell characterization and quantification remain challenging in pathologic samples, whereas slide reviews due to unnecessary flagging should be avoided. We compared 4 modern hematology analyzers-Abbott Sapphire, Siemens Advia 120, Sysmex XE-2100, and Beckman Coulter DxH 800-regarding complete blood cell count (CBC), leukocyte differential count, and flagging efficacy in ...

متن کامل

Reliable, Accurate Determination of the Leukocyte Differential of Leukopenic Samples by Using Hematoflow Method

BACKGROUND Hematology analyzers may ineffectively recognize abnormal cells, and manual differential counts may be imprecise for leukopenic samples. We evaluated the efficacy of the Hematoflow method for determining the leukocyte differential in leukopenic samples and compared this method with the manual differential method. METHODS We selected 249 blood samples from 167 patients with leukopen...

متن کامل

White blood cell differential counts in severely leukopenic samples: a comparative analysis of different solutions available in modern laboratory hematology

BACKGROUND We evaluated the efficacy of white blood cell (WBC) differential counts in severely leukopenic samples by the Hematoflow method and by automated hematology analyzers and compared the results with manual counts. METHODS EDTA-anticoagulated blood samples (175 samples) with WBC counts of 40-990/µL were selected. Hematoflow differential counts were performed in duplicates employing flo...

متن کامل

Peykan check, a simple continuous quality control method for hematology analyzers

A simple inexpensive con!nuous quality control method, by means of eight basic blood coun!ng parameters, obtained from automated hematology analyzers, using pa!ent samples, is described. A few samples with low, normal and high values were selected and introduced to the instrument early in the morning as the first count, the results of which are plo#ed on the appropriate chart as dots. The sa...

متن کامل

[Current status and proposal of a guideline for manual slide review of automated complete blood cell count and white blood cell differential].

BACKGROUND Manual slide review (MSR) is usually triggered by the results of automated hematology analyzers, but each laboratory has different criteria for MSR. This study was carried out to investigate the current status of MSR criteria of automated complete blood cell count (CBC) and white blood cell (WBC) differential results and to propose a basic guideline for MSR. METHODS Total 111 labor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Korean journal of laboratory medicine

دوره 30 6  شماره 

صفحات  -

تاریخ انتشار 2010