Observation of Return Current Effects in a Passive Plasma Lens
نویسندگان
چکیده
Observations of relativistic beam focusing by a passive plasma lens have demonstrated a reduction in focusing strength due to plasma return current. A 50 MeV beam was propagated through a 1–3 cm long plasma with density around 1014 cm23. Beam size was measured as a function of propagation distance. For a ratio of collisionless plasma skin depth to beam spot size kpsr 0.33, no significant reduction in focusing was observed. Reduced focusing was measured for kpsr 1.1, where a significant fraction of the inductively driven return current in the plasma flows within the beam. The observations are in good agreement with an envelope equation model and with particle-in-cell simulations.
منابع مشابه
Oral Morphine Consumption Reduces Lens Development in Rat Embryos
Introduction: Consumption of morphine, during pregnancy, in addition to inducing defects in the mother’s nervous system function, caused defects or delays in the formation and evolution of embryonic visual system. In the present study, changes in lens development were assessed in embryos exposed to morphine in utero. Methods: Female Wistar rats (250-300 g) were mated with male rats and pregnanc...
متن کاملElectrically switchable cylindrical Fresnel lens based on holographic polymer-dispersed liquid crystals using a Michelson interferometer
Fabricating an electrically switchable cylindrical Fresnel lens based on holographic polymer-dispersed liquid crystals (H-PDLC) using a Michelson interferometer is reported. Simplicity of the method and possibility of fabricating different focal length lenses in a single set up are among the advantages of the method. It is demonstrated that the Fresnel structured zone plate acts as a cylindrica...
متن کاملAn investigation on the passivation behavior of nitrogen enriched AISI 316L austenitic stainless steel
In the present work the effects of plasma nitridization on the passivation behavior of AISI 316L was investigated. To do this; nitriding treatments were carried out at 420°C for 1, 2, 4 and 16 hours. The phase composition and structure of the nitrided layer were studied by Low Angle X-ray diffraction and Scanning Electron Microscopy. The hardness of samples also was evaluated by Vickers microha...
متن کاملStudying the effects of pH and molecular charge on the passive and iontophoretic permeation of L-phenylalanine through cellulose acetate membrane
Iontophoresis is one of the skin permeation enhancement methods involving the transport of drugs through the skin under the effect of electrical current. The effect of molecular charge on the iontophoretic permeation of drugs has not been completely understood yet. Therefore the effect of passive and iontophoretic permeation of L-phenylalanine at pH 3.6 (positive charge) and pH 8 (negative ch...
متن کاملModelling of new generation plasma optical devices
The crossed electric and magnetic fi elds, inherent to the cylindrical electrostatic plasma lens (PL) confi guration, provide an attractive method for establishing a stable plasma discharge at a low pressure [1]. One particularly interesting result of this background work was the observation of the essential positive potential at the fl oating substrate. This suggested that an electrostatic PL ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1999