Impact of Heterogeneous Overlapping Drug-Eluting Stents on the Arterial Responses of Rabbit Iliac Arteries: A Comparison With Overlapping Bare Metal Stents

نویسندگان

  • Seung-Woon Rha
  • Kang-Yin Chen
  • Dong Joo Oh
  • Yong-Jian Li
  • Zhe Jin
  • Kanhaiya Lal Poddar
  • Sureshkumar Ramasamy
  • Yoshiyasu Minami
  • Amro Elnagar
  • Byoung Geol Choi
  • Sang Pyo Hong
  • Byoung Won Cheon
  • Sang Ki Moon
  • Sung Il Im
  • Sun Won Kim
  • Jin Oh Na
  • Cheol Ung Choi
  • Hong Euy Lim
  • Jin Won Kim
  • Eung Ju Kim
  • Seong Woo Han
  • Chang Gyu Park
  • Hong Seog Seo
  • Jung Ha Kim
  • Young Joon Hong
  • Myung Ho Jeong
چکیده

BACKGROUND AND OBJECTIVES Although the use of heterogeneous overlapping drug-eluting stents (DES) is not uncommon in clinical practice, whether the implantation sequences of heterogeneous DES will influence the endothelialization or arterial responses differently remains unclear. MATERIALS AND METHODS Twenty-one rabbits were randomized to receive overlapping stents in the iliac artery for 3 months {distal sirolimus-eluting stent (SES, Cypher™)+proximal paclitaxel-eluting stent (PES, Taxus™) (C+T, n=7), distal Taxus+proximal Cypher (T+C, n=7) and bare metal stent (BMS)+BMS (B+B, n=7)}. Endothelial function was evaluated by the acetylcholine provocation test during follow-up angiography. Histopathological changes in proximal, overlapped, and distal stented segments were evaluated. RESULTS Although the overall angiographic outcomes were comparable, late loss (mm) in the distal stented segment was higher in the B+B (0.39±0.07) and C+T (0.40±0.20) than that in the T+C (0.06±0.02) group (p<0.001). The incidence of acetylcholine-induced spasm was higher in the DES groups compared with BMS, regardless of the implantation sequences (85.7% in C+T vs. 14.3% in B+B vs. 71.4% in T+C, p=0.017). Notably, only the distal Cypher implantation group (C+T) had three cases of stent fracture. A histopathological analysis showed that despite similar arterial injury scores, Taxus and Cypher stents had higher inflammatory reactions at the overlapped and distal segments compared with those of BMS. CONCLUSION Despite similar arterial injury, higher inflammatory reactions were observed in overlapping DES segments regardless of the implantation sequence compared with that of BMS. Moreover, DES was associated with impaired endothelial function on the adjacent non-stented segments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Differential response of delayed healing and persistent inflammation at sites of overlapping sirolimus- or paclitaxel-eluting stents.

BACKGROUND Although effective coverage of challenging coronary lesions has warranted the use of overlapping drug-eluting stents, the histopathological response to stent overlap is unknown. METHODS AND RESULTS The arterial reaction to overlapping Cypher or Taxus drug-eluting stents was examined in rabbits with bare metal stents, BxVelocity or Express, serving as controls. Single iliac artery b...

متن کامل

VASCULAR BIOLOGY Original Studies In Vivo Comparison of a Polymer-Free Biolimus A9-Eluting Stent With a Biodegradable Polymer-Based Biolimus A9 Eluting Stent and a Bare Metal Stent in Balloon Denuded and Radiated Hypercholesterolemic Rabbit Iliac Arteries

Objectives: To evaluate the effect of a polymer-free Biolimus A9-eluting stent [BioFreedom (BF)], compared with that of a biodegradable polymer-based Biolimus A9-eluting stent [BioMatrix Flex (BMF)] and a bare metal stent (BMS) in balloon denuded and radiated hypercholesterolemic rabbit iliac arteries. Methods: Rabbits were fed with 1% cholesterol diet (n 5 14) for 14 days, both iliac arteries ...

متن کامل

An advection-diffusion multi-layer porous model for stent drug delivery in coronary arteries

Arterial drug concentration distribution determines local toxicity. The safety issues dealt with Drug-Eluting Stents (DESs) reveal the needs for investigation about the effective factors contributing to fluctuations in arterial drug uptake. The current study focused on the importance of hypertension as an important and controversial risk factor among researchers on the efficacy of Heparin-Eluti...

متن کامل

Optical coherence tomography assessment of in vivo vascular response after implantation of overlapping bare-metal and drug-eluting stents.

OBJECTIVES We designed a randomized trial exploiting optical coherence tomography (OCT) to assess coverage and apposition of overlapping bare-metal stents (BMS) and drug-eluting stents (DES) in human coronary arteries. BACKGROUND Overlapping DES impair healing in animals. Optical coherence tomography allows accurate in vivo assessment of stent strut coverage and apposition. METHODS Seventy-...

متن کامل

A novel model of in-stent restenosis: rat aortic stenting.

S irolimus eluting stents are associated with very low restenosis rates when deployed for single de novo native coronary lesions. These and other drug eluting stents are changing the face of interventional cardiology practice. A number of fundamental practical questions arise with the use of these novel stents, including the effects on in-stent restenosis (ISR) of overlapping stents, tandem ste...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 42  شماره 

صفحات  -

تاریخ انتشار 2012