Development and Validation of a Stability-Indicating Assay of Etofenamate by RP-HPLC and Characterization of Degradation Products
نویسندگان
چکیده
A validated stability-indicating RP-HPLC method for etofenamate (ETF) was developed by separating its degradation products on a C18 (250 mm × 4.6 mm 5 μm) Qualisil BDS column using a phosphate buffer (pH-adjusted to 6.0 with orthophosphoric acid) and methanol in the ratio of 20:80 % v/v as the mobile phase at a flow rate of 1.0 mL/min. The column effluents were monitored by a photodiode array detector set at 286 nm. The method was validated in terms of specificity, linearity, accuracy, precision, detection limit, quantification limit, and robustness. Forced degradation of etofenamate was carried out under acidic, basic, thermal, photo, and peroxide conditions and the major degradation products of acidic and basic degradation were isolated and characterized by (1)H-NMR, (13)C-NMR, and mass spectral studies. The mass balance of the method varied between 92-99%.
منابع مشابه
Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملRapid Analysis of Glibenclamide Using an Environmentally Benign Stability-Indicating RP-HPLC Method
An environmentally benign RP-HPLC approach for rapid analysis of glibenclamide in pure form, developed nanoemulsion and commercial tablets was developed and validated in present investigation. The green chromatographic identification was performed on Lichrosphere 250 X 4.0 mm RP C8 column having a 5µm packing as a stationary phase using a combination of ethanol: methanol (50:50 % v/v) as a mobi...
متن کاملRapid Analysis of Glibenclamide Using an Environmentally Benign Stability-Indicating RP-HPLC Method
An environmentally benign RP-HPLC approach for rapid analysis of glibenclamide in pure form, developed nanoemulsion and commercial tablets was developed and validated in present investigation. The green chromatographic identification was performed on Lichrosphere 250 X 4.0 mm RP C8 column having a 5µm packing as a stationary phase using a combination of ethanol: methanol (50:50 % v/v) as a mobi...
متن کاملA Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form
A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a reten...
متن کامل