Water permeability of cat corneal endothelium in vitro.

نویسندگان

  • S W Rhee
  • K Green
  • M Martinez
  • D Paton
چکیده

A water permeability study of the isolated cat corneal endothelium was performed with the use of a newly designed Lucite chamber and modified experimental methods. The hydraulic conductivity of the cat endothelium was 9.3 ± 1.09 x 10~ cm. seer atmr. The Staverman reflection coefficient to NaCl of cat endothelium was 0.6. It was determined that the resistance to the passage of either water or small solutes is negligible in the swollen stroma. The results suggest that the intercellular space of the cat endothelium is less tlian that of the rabbit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of ouabain on the rabbit corneal endothelium.

With the method of in vitro incubation of the isolated rabbit cornea with the modified KEI medium, the effects of ouabain applied to the endothelial surface have been investigated. The change in corneal hydration with varying concentrations of ouabain was determined; one-half maximum rate of corneal swelling was found at an ouabain concentration of 3 x 10~ moles per liter. Endothelial permeabil...

متن کامل

Permeability of the corneal endothelium to nonelectrolytes.

The endothelial surface of the isolated rabbit cornea was perfused with modified KEI medium, according to the method reported previously. This in vitro cornea maintained its thickness within the normal range even after the epithelium ivas removed. The endothelial permeability of these in vitro corneas to tritiated water, >C-labeled urea, sucrose, and inulin teas determined. The reflection coeff...

متن کامل

Corneal membrane water permeability as a function of temperature.

Osmotically driven water flow across the corneal epithelium and endothelium has been measured as a function of temperature. For both membranes deviations from a single straight-line relationship are found in a logarithmic plot of hydraulic conductivity against 1/T. Both membranes show a high (14 to 16 kcal per mole) apparent activation energy at temperatures between 23 degrees C. and 5 degrees ...

متن کامل

Paracellular permeability of corneal and conjunctival epithelia.

The paracellular permeability of normal rabbit cornea and conjunctiva was studied in vivo and in vitro. After intravenous administration, horseradish peroxidase was found to percolate to the intercellular space of conjunctival epithelia and was restricted by the tight junctions of the superficial epithelium. Only minimal tracer was present in the limbus and cornea. The difference between cornea...

متن کامل

Studies on the cornea. VII. Effects of perfusion with a Ca++-free medium on the corneal endothelium.

Paired isolated corneas were perfused in vitro with a modified KEI medium according to the method of Mishima and Kudo. One eye of each pair was perfused with the complete medium and the other with a Ca-free medium. Progressive corneal swelling occurred in the Ca-free medium. The swollen corneas had a greatly increased passive permeability to nontransported nonelectrolytes, suggesting a physical...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology

دوره 10 4  شماره 

صفحات  -

تاریخ انتشار 1971