Optimizing radiation protection of the operator during cardiac catheterization by minimizing the effective dose

نویسندگان

  • Heiner von Boetticher
  • Jörn Lachmund
  • Wolfgang Hoffmann
  • Helmut W. Lange
چکیده

Radiation exposure dosimetry for the personnel is based on measurements of phantom studies. To determine effective dose values for different X-ray equipment, TLD-measurements were performed using an Alderson Phantom in the patient position and a second phantom in the typical position of the personnel. Various types of protective clothing as well as fixed shields were considered in the calculations. Additional thyroid protection collars reduce the effective dose by a factor of 1.8-2.6. In the sense of effective dose X-ray protective clothing with 0.35 mm lead equivalent and an additional thyroid protection collar provide a better protection against radiation than an apron with 0.5 mm lead equivalent without collar. The doses of the unshielded organs (thyroid, parts of the active bone marrow) contribute significantly to the effective dose of the staff. Therefore an additional shielding of these organs reduces the effective dose more than an increase of the lead equivalency of the existing apron. We recommend face shields and thyroid protection collars as a necessary part of anti-X protection for cardiac catherization laboratories.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reduction of operator radiation dose by a pelvic lead shield during cardiac catheterization by radial access: comparison with femoral access.

OBJECTIVES This study sought to determine the efficacy of patient pelvic lead shielding for the reduction of operator radiation exposure during cardiac catheterization via the radial access in comparison with the femoral access. BACKGROUND Cardiac catheterization via the radial access is associated with significantly increased radiation dose to the patient and the operator. Improvements in ra...

متن کامل

Evaluation of the annual effective dose to Cath Lab staff in the Afshar Hospital, Yazd and suggesting the radiation protection strategies to better management of occupational dose

Introduction Due to the increasing use of angiography procedures and the higher risk of deterministic and stochastic effects for radiation workers of these sections than other radiological procedures, radiation safety is very important in angiography staff. So, this study aimed to obtain the effective dose of angiography staff and compare them with the standard dose limit and finally outline th...

متن کامل

Effective Dose of Radiation in Diagnostic and Interventional Cardiac Angiography among Pediatrics and Adolescents in Hospitals of Shiraz University of Medical Sciences versus Other Radiology Devices

Background: Cardiac catheterization and angiography are diagnostic and therapeutic imaging modalities that produce the highest X-ray radiation, which might impose lifelong risks to patients. This study aimed to evaluate radiation burden among children and adolescents with congenital heart diseases, who underwent cardiac catheterization and angiography. Then the results were compared with other ...

متن کامل

Assessment of Patient Absorbed Radiation Dose during Hysterosalpingography: A Pilot Study in Southwest Nigeria

Background: Hysterosalpingography (HSG) is an indispensable tool for diagnosing infertility in females. The procedure exposes female reproductive organs to ionizing radiation as the genitals are irradiated during the process. Investigating patient absorbed dose during the procedures is essential for effective radiological protection of the patient. Objective: This study aims to investigat...

متن کامل

Recommendations for occupational radiation protection in interventional cardiology.

The radiation dose received by cardiologists during percutaneous coronary interventions, electrophysiology procedures and other interventional cardiology procedures can vary by more than an order of magnitude for the same type of procedure and for similar patient doses. There is particular concern regarding occupational dose to the lens of the eye. This document provides recommendations for occ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008