Statistically stable ultrasonic imaging in random media.
نویسندگان
چکیده
Analysis of array data from acoustic scattering in a random medium with a small number of isolated targets is performed in order to image and, thereby, localize the spatial position of each target. Because the host medium has random fluctuations in wave speed, the background medium is itself a source of scattered energy. It is assumed, however, that the targets are sufficiently larger and/or more reflective than the background fluctuations so that a clear distinction can be made between targets and background scatterers. In numerical simulations nonreflective boundary conditions are used so as to isolate the effects of the host randomness from those of the spatial boundaries, which can then be treated in a separate analysis. It is shown that the key to successful imaging is finding statistically stable functionals of the data whose extreme values provide estimates of scatterer locations. The best ones are related to the eigenfunctions and eigenvalues of the array response matrix, just as one might expect from prior work on array data processing in complex scattering media having homogeneous backgrounds. The specific imaging functionals studied include matched-field processing and linear subspace methods, such as MUSIC (MUtiple SIgnal Classification). But statistical stability is not characteristic of the frequency domain, which is often the province of these methods. By transforming back into the time domain after first diagonalizing the array data in the frequency domain, one can take advantage of both the time-domain stability and the frequency-domain orthogonality of the relevant eigenfunctions.
منابع مشابه
Carboxyl of Poly(D,L-lactide-co-glycolide) Nanoparticles of Perfluorooctyl Bromide for Ultrasonic Imaging of Tumor
Perfluorooctyl bromide (PFOB) enclosed nanoparticles (NPs) as ultrasonic contrasts have shown promising results in the recent years. However, NPs display poor contrast enhancement in vivo. In this work, we used the copolymers poly(lactide-co-glycolide) carboxylic acid (PLGA-COOH) and poly(lactide-co- glycolide) poly(ethylene glycol) carboxylic acid (PLGA-PEG-COOH) as a shell to encapsulate PFOB...
متن کاملPhased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test
One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...
متن کاملPhased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test
One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...
متن کاملStatistical stability and time-reversal imaging in random media
Localization of targets imbedded in a heterogeneous background medium is a common problem in seismic, ultrasonic, and electromagnetic imaging problems. The best imaging techniques make direct use of the eigenfunctions and eigenvalues of the array response matrix, as recent work on time-reversal acoustics has shown. Of the various imaging functionals studied, one that is representative of a pref...
متن کاملAdaptive interferometric imaging in clutter and optimal illumination
A frequently used broadband array imaging method is Kirchhoff or travel time migration. In smooth and known media Kirchhoff migration works quite well, with range resolution proportional to the reciprocal of the bandwidth and cross range resolution that is proportional to the reciprocal of the array size. In a randomly inhomogeneous medium, Kirchhoff migration is unreliable because the images d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of the Acoustical Society of America
دوره 112 4 شماره
صفحات -
تاریخ انتشار 2002