Micromechanical measurement of active sites on silicon nitride using surface free energy variation.
نویسندگان
چکیده
We have investigated chemical reactions between adsorbed water and active sites on a silicon nitride surface as a function of temperature and relative humidity using microcantilevers. Effects that might produce a change in the response of the microcantilever, such as a mass adsorption, surface tension of the adsorbed water, and changes in thermal conductivity, were systematically investigated. It is shown that the judicious choice of experimental conditions could make these effects essentially inconsequential in comparison with the instrument response produced by the change in free surface energy of the microcantilever due to the chemical reactions. Using this method, the variation in free surface energy when changing from dry to high humidity conditions was found and the number of active sites that reacted was estimated. This method may be extended to other problems for use in determining surface free energy change and thus the density of reactant sites under different conditions of interest.
منابع مشابه
Micromachined Sensor and Actuator Research at the Microelectronics Development Laboratory
An overview of the major sensor and actuator projects using the micromachining capabilities of the Microelectronics Development Laboratory at Sandia National Laboratories will be presented. Development efforts are underway for a variety of micromechanical devices and control electronics for those devices. Surface micromachining is the predominant technology under development. Pressure sensors b...
متن کاملTheoretical study of 2,3,7,8-tetrachlorodibenzo-para-dioxine removal by boron nitride-nanotube (BNNT): QSAR, IR-DFT
The study examined corrosion inhibition of corrosion inhibition of 5-methyl-2H-imidazol-4-carboxaldehyde and 1H-Indole-3-carboxaldehyde on mild steel in acidic medium using weight loss and Density Functional Theory (DFT) methods. DFT calculations were carried out at B3LYP/6-31+G** level of theory in aqueous medium on the molecular structures to describe electronic parameters. The values of ther...
متن کاملNumerical Modeling of Non-equilibrium Plasma Discharge of Hydrogenated Silicon Nitride (SiH4/NH3/H2)
In this work, we model a radiofrequency discharge of hydrogenated silicon nitride in a capacitive coupled plasma reactor using Maxwellian and non-Maxwellian electron energy distribution function. The purpose is to investigate whether there is a real advantage and a significant contribution using non-Maxwellian electron energy distribution function rather than Maxwellian one for determining the ...
متن کاملFour-wire orthogonal structure for accurate measurement of fluid velocity and wind flow direction using silicon micro-machining on silicon nitride membranes
Microelectromechanical thermal sensors are one of the most accurate and important tools for measuring the direction and velocity of an acoustic wave and winds. Detection of wind direction and speed in different ranges has different applications such as meteorology, wind power plants, gas flow measurement in smart building and gas consumption of power plants. In this paper, a four wires sensor i...
متن کاملDetection of pH variation using modi®ed microcantilever sensors
A micromechanical technique for measuring solution pH using modi®ed silicon (SiO2) and silicon nitride (Si3N4) microcantilevers is described. As the modi®ed surface of the cantilever accumulates charge proportional to the pH of the surrounding liquid, the cantilever undergoes bending due to the differential surface stress. Results are presented for chemically modi®ed (4-aminobutyltriethoxysilan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultramicroscopy
دوره 91 1-4 شماره
صفحات -
تاریخ انتشار 2002