The Scandinavian multicenter hemodynamic evaluation of the SJM Regent aortic valve

نویسندگان

  • Jon Offstad
  • Kai Andersen
  • Per Paulsson
  • Jesper Andreasson
  • Ulf Kjellman
  • Oluf Lundblad
  • Karl Gunnar Engstrøm
  • Rune Haaverstad
  • Jan L Svennevig
چکیده

BACKGROUND 112 patients who received small and medium sized St. Jude Regent heart valves (19-25 mm) at 7 Scandinavian centers were studied between January 2003 and February 2005 to obtain non-invasive data regarding the hemodynamic performance at rest and during Dobutamine stress echocardiography (DSE) testing one year after surgery. MATERIAL AND METHODS 46 woman and 66 men, aged 61.8 ± 9.7 (18-75) years, were operated on for aortic regurgitation (17), stenosis (65), or mixed dysfunction (30). Valve sizes were 19 mm (6), 21 mm (33), 23 mm (41), 25 mm (30). Two patients receiving size 27 valves were excluded from the hemodynamic evaluation. Pledgets were used in 100 patients, everted mattress in 66 and simple interrupted sutures in 21. Valve orientation varied and was dependent on the surgeons' choice. 34 patients (30.4%) underwent concomitant coronary artery surgery. RESULTS There were two early deaths (1.8%) and three late deaths, one because of pancreatic cancer. Late events during follow-up were: non structural dysfunction (1), bleeding (2), thromboembolism (2). At one year follow up 93% of the patients were in NYHA classes 1-2 versus 47.8% preoperatively. Dobutamine stress echocardiography (DSE) was performed in a total of 66 and maximal peak stress was reached in 61 patients. During DSE testing, the following statistically significant changes took place: Heart rate increased by 73.0%, cardiac output by 85.5%, left ventriclular ejection fraction by 19.6%, and maximal mean prosthetic transvalvular gradient by 133.8%, whereas the effective orifice area index did not change. Left ventricular mass fell during one year from 215 ± 63 to 197 ± 62 g (p < 0.05). CONCLUSION The Dobutamine test induces a substantial stress, well suitable for echocardiographic assessment of prosthesis valve function and can be performed in the majority of the patients. The changes in pressure gradients add to the hemodynamic characteristics of the various valve sizes. In our patients the St. Jude Regent valve performed satisfactory at rest and under pharmacological stress situation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A case of aortic valve replacement with St. Jude Medical Regent valve (first implant in Japan).

The St. Jude Medical (SJM) Regent valve was developed as a new mechanical valve by improving the conventional SJM valve. The effective orifice area is wider than that of Hemodynamic Plus (HP) series. The efficacy of the new valve has been reported in Europe and the United States. On October 26, 2004, we first performed aortic valve replacement (AVR) with the SJM Regent valve for aortic valve st...

متن کامل

On-X versus St Jude Medical Regent mechanical aortic valve prostheses: early haemodynamics

OBJECTIVE We aimed to compare the early haemodynamic data of the On-X and St Jude Medical (SJM) Regent bileaflet mechanical prostheses in the aortic position. METHODS A retrospective study was performed using data collected prospectively for a national database. Thirty-three patients who had aortic On-X valve (On-X group) and 33 matched patients who had aortic SJM Regent valve (SJM group) wer...

متن کامل

Application of Regent mechanical valve in patients with small aortic annulus: 3-year follow-up

BACKGROUND Aortic valve replacement (AVR) with a small aortic annulus is always challenging for the cardiac surgeon. In this study, we sought to evaluate the midterm performance of implantation with a 17-mm or 19-mm St. Jude Medical Regent (SJM Regent) mechanical valve in retrospective consecutive cohort of patients with small aortic annulus (diameter ≤ 19 mm). METHODS From January 2008 to Ap...

متن کامل

Comparison of the hemodynamic and thrombogenic performance of two bileaflet mechanical heart valves using a CFD/FSI model.

The hemodynamic and the thrombogenic performance of two commercially available bileaflet mechanical heart valves (MHVs)--the ATS Open Pivot Valve (ATS) and the St. Jude Regent Valve (SJM), was compared using a state of the art computational fluid dynamics-fluid structure interaction (CFD-FSI) methodology. A transient simulation of the ATS and SJM valves was conducted in a three-dimensional mode...

متن کامل

Evaluation of St. Jude Medical valve's long-term function by Doppler echocardiography.

In this study, the long-term function of St. Jude Medical valve (SJM valve) is evaluated by Doppler echocardiography. The subjects were 191 patients who underwent mitral or aortic valve replacement using SJM valve in our institute since July 1978 and had no clinical problem showing more than 50% of left ventricular ejection fraction. The patients were classified into 3 groups according to measu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2011