Can the oxygenator screen filter reduce gaseous microemboli?

نویسندگان

  • Daniel Johagen
  • Micael Appelblad
  • Staffan Svenmarker
چکیده

Gaseous microemboli (GME) define small bubbles as < 200 microm in size. GME are reported to increase morbidity after cardiopulmonary bypass (CPB) and cardiac surgery. To prevent intrusion of GME into the systemic circulation during CPB, arterial line filtration is generally recommended. New trends in oxygenator design promote location of arterial filtration as an integral part of the oxygenator housing. The present experimental study aimed to evaluate the GME removal properties of an integrated arterial screen filter in a standard microporous oxygenator. The GME properties of Terumo Capiox FX25 with an integrated arterial screen filter was assessed in an experimental setup and compared with Capiox RX25, in which no arterial screen filter is present. A blood analog prime solution was recirculated using a roller pump at 4 and 6 L per minute flow rate, respectively, through a customized CPB circuit comprising oxygenator, reservoir, and connecting tubing. A controlled volume of air was introduced into the circuit. The GME activity was measured and computed using a Gampt BCC200 ultrasonic device placing one probe at the venous inlet and one other at the arterial outlet of the oxygenator. Transmembrane delta values of GME activity were used to calculate the removal efficacy based on counts and volume of GME. Use of screen filtration reduced the GME volume by 99.1% +/- .1% compared with 98.0% +/- .1% for controls at 4 L/min flow rate (p < .001). At 6 L/min, the reduction was 97.9% +/- .1% compared with 97.0% +/- .1% (p < .001). In contrast, the reduction of GME counts was less effective after screen filtration compared with controls: 89.6 +/- .6% versus 91.4 +/- .4% at 4 L/min and 55.6% +/- 1.6% versus 76.0% +/- 1.4% at 6 L/min, respectively (p < .001). The tested oxygenator with incorporated arterial screen filter reduced GME activity based on the calculated volume at the same time as counts of GME increased.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gaseous Emboli Removal Efficiency in Arterial Screen Filters: A Comparative Study

____________ _ Seven commercially available arterial filters were evaluated for their effectiveness in removing gaseous emboli produced by various sources. All filters were of the screen type and ranged from 2040 micron pore size. The first phase of the study consisted of an appraisal of carbon dioxide flushing to facilitate priming. Two filters of each type were used. The first filter was prim...

متن کامل

ECC Sources of Gaseous Microemboli

___________ _ We have tried to locate sources of gaseous microemboli during the ECC using a newly developed ultrasonic detector. The detector was calibrated with filters of known pore size and the recorder setting was kept constant at all times. We studied, at the oxygenator, the effect of low and high fill volume, refilling with or without air into the cardiotomy line, mechanical disturbance, ...

متن کامل

Gaseous microemboli in a pediatric bypass circuit with an unprimed venous line: an in vitro study.

Miniaturizing cardiopulmonary bypass (CPB) circuits to reduce hemodilution and allogenic blood product administration is common in cardiac surgery. One major concern associated with smaller CPB circuits is a possible increase in gaseous microemboli (GME) sent to the cerebral vasculature, which is exacerbated by vacuum-assisted venous drainage (VAVD). The use of VAVD has increased with smaller v...

متن کامل

Comparison of gaseous microemboli counts in arterial, simultaneous and venous heat exchange with a hollow fiber membrane oxygenator.

Potential sources of gaseous microemboli during cardiopulmonary bypass are varied. However, it is known that membrane oxygenators generate fewer gaseous microemboli than bubble oxygenators and that bubblers cannot utilize arterial heat exchange without generating significant gaseous microemboli during rewarming. A membrane oxygenator utilizing simultaneous gas and heat exchange raises the con...

متن کامل

Gaseous microemboli: do we finally start to comprehend how to remove them?

Since the early introduction of cardiopulmonary bypass, gaseous microemboli (GME) have been considered one of the potential causes of neurological deficit (1). A major step in attenuating the number of GME was the introduction of the arterial screen filter (2). The working principle of the filter is twofold; the filter screen creates a mechanical barrier for GME larger than its pore size and si...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 46 1  شماره 

صفحات  -

تاریخ انتشار 2014