Primary Total Hip Arthroplasty Using Third Generation Ceramic-Ceramic Articulation: Results after a Minimum of Three-years of Follow-up
نویسندگان
چکیده
PURPOSE This study assessed the short term clinicoradiological results of primary total hip arthroplasty using third generation ceramic-ceramic articulation Accolade TMZF femoral stems. MATERIALS AND METHODS Two hundred and seventy two patients (294 hips) with primary total hip arthroplasty using third generation ceramic-ceramic articulation Accolade TMZF femoral stems who had been followed-up for a minimum of 3 years were included. Clinicoradiological results were analyzed and postoperative complications were observed. RESULTS At final follow-up, mean Harris hip score was increased from 52 to 94 points. On radiogical evaluation, the average acetabular inclination was 42 degrees and the average acetabular anteversion was 15 degrees. Neither osteolysis nor loosening were observed around the acetabulum or proximal femur. Among 294 acetabular cups, 293 cups (99.66%) achieved stable fixation. Regarding the 294 femoral stems, 286 (97.28%) had bony fixation, 7 (2.38%) had fibrous fixation, and none were found to have unstable stem fixation. Proximal bone resorption was observed in 17 hips (5.78%; only Grade 1) and radiolucent lines were observed in 88 hips (29.93%), however, all were around the distal smooth portion of the stems. Postoperative complications included dislocation in 6 hips (2.04%), heterotopic ossification in 3 hips (1.02%), ceramic fractures in 4 hips (1.36%), superficial infection in 1 hip (0.34%), and squeaking in 8 hips (2.72%). CONCLUSION The short term clinicoradiological results of primary total hip arthroplasty using third generation ceramic-ceramic articulation and Accolade TMZF femoral stems together with Secur-Fit acetabular cups were satisfactory. However, problems such as ceramic fractures and squeaking after arthroplasty were observed. Additional studies are necessary in order to develop methods that may reduce or eliminate these complications.
منابع مشابه
Cementless Revision Total Hip Arthroplasty with Ceramic Articulation
PURPOSE The results of ceramic-on-ceramic (CoC) bearing surfaces in primary total hip arthroplasty (THA) were well known. However, it was not known in revision THA. The purpose of this study is to report the results of revision THA with ceramic articulation. MATERIALS AND METHODS A total of 112 revision THAs were evaluated. The mean age at the time of surgery was 51.6 years (27.7 to 84.2 year...
متن کاملFatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature
Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...
متن کاملAlumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study.
BACKGROUND Ceramic-on-ceramic couplings are attractive alternative bearing surfaces that have been reported to eliminate or reduce problems related to polyethylene wear debris. Disappointing experiences with alumina ceramic bearings in the past have led to many improvements in the manufacture and design of ceramic implants. The purpose of the present study was to report the results of contempor...
متن کاملAlumina-on-alumina total hip arthroplasty: a concise follow-up, at a minimum of ten years, of a previous report.
We previously reported the five-to-six-year results of the use of third-generation alumina-on-alumina bearings in a consecutive series of 100 primary cementless total hip arthroplasties. This report presents the longer-term outcomes of these same bearings, at a minimum of ten years postoperatively. Eighty-six of eighty-eight hips available for the study retained the original bearings at the tim...
متن کاملFracture of ceramic components as a serious failure after total hip replacement with ceramic-on-ceramic bearings
Introduction Ceramics have been introduced in total hip arthroplasty for several advantages including minimal friction, low wear, biocompatibility, no ageing problems and no problems related to the systemic increases in serum metal concentrations. In the first generation of ceramic components introduced in the 1970’s the risk of fracture was substantial, reaching up to 13.4 %. After introducing...
متن کامل