Beam Position Monitor System for the Orbit Feedback at the Interaction Region of Kekb

نویسندگان

  • Masaki Tejima
  • Kotaro Satoh
  • Makoto Tobiyama
چکیده

To maintain the optimum collision condition of the two rings, two special BPMs with 8-button electrodes, called OCTPOS, were installed inside the super-conducting quadrupole magnets (QCSs) at the interaction region (IR) of KEKB. Four normal BPMs with 4-button electrodes were incorporated outside the QCSs. We have commissioned the OCTPOS BPMs for simultaneous measurements of both the electron and positron beam positions from their composite signal. We have verified the separation of both beams by the finite orbit separation method. The beam positions of OCTPOS and four normal BPMs were consistent. This report describes the performance of the system as a result of operation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Special Beam Position Monitor with 8-button Electrodes for the Kekb Interaction Region

To maintain the optimum collision condition of the two beams, two special BPMs with 8-button electrodes, called OCTOPOS, were installed inside the super-conducting quadrupole magnets (QCSs) at the interaction region (IR) of KEKB. We have commissioned the OCTOPOS BPMs for simultaneous measurements of both the electron and positron beam positions from their composite signal. A collision orbital f...

متن کامل

Beam Feedback Systems and Bpm Read-out System for the Two-bunch Acceleration at Kekb Linac

In order to double the positron injection rate into the KEKB ring, a two-bunch acceleration scheme has been studied at the linac, in which bunches separated by 96 ns are accelerated in 50 Hz. In this scheme the stabilization of energy and orbit of each bunch is indispensable. Thus the beam energy and orbit feedback systems have been upgraded. Since beam characteristics are acquired through beam...

متن کامل

Optics Measurement at the Interaction Point Using Nearby Position Monitors in Kekb

Optics parameters at the interaction point, beta, x-y coupling, dispersion and their chromatic aberrations, seriously affect the beam-beam performance as is shown in experiments and simulations. The control of the optics parameters is essential to maintain the high luminosity in KEKB. They drift day by day, or before and after the beam abort. They were often monitored at intervals of the operat...

متن کامل

KEKB Beam Instrumentation Systems

For the stable high-luminosity operation and luminosity-increase, the electron and positron storage rings of the KEK B-Factory (KEKB) is equipped with various beam instrumentations, which have being working well since the start of the commissioning in December, 1998. Details and performance of the beam-position monitor system based on the spectrum analysis using DSPs, the turn by turn BPM with ...

متن کامل

Beam Switching and Beam Feedback Systems at Kekb Linac

The KEK 8-GeV electron / 3.5-GeV positron linac has been operated with very different beam specifications for downstream rings, KEKB, PF and PF-AR. For the reliable operation among these beam modes, intelligent beam switching and beam feedback systems have been developed and used since its commissioning. A software panel is used to choose one of four beam modes and a switching sequence is execu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001