A Method to Prepare a Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) Graft Using Donor Corneas With Narrow Scleral Rims
نویسندگان
چکیده
Donor corneas with narrow scleral rims are often disqualified for Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK), mainly because of fluid leak and low pressure when they are mounted onto an artificial anterior chamber (AAC). This report describes a novel method to tight-lock a donor cornea with a narrow scleral rim so that microkeratome cutting is possible, allowing a DSAEK procedure to be completed. A 50-year-old male suffering from Epstein-Barr virus (EBV) endotheliitis with resulting corneal edema in his left eye was the subject of this study. His best corrected visual acuity (BCVA) was 20/600. The patient underwent a DSAEK procedure; however, the microkeratome cutting of the donor cornea initially failed due to its narrow scleral rim, which caused the balance salt solution (BSS) to leak out of the AAC. A doughnut-shaped cushion was made from a surgical glove, which enabled a tight lock of the cornea to the AAC, enabling the chamber pressure to be raised and the microkeratome cutting to be completed. A subsequent DSAEK procedure was performed uneventfully. Postoperatively, the patient received oral valganciclovir 450 mg b.i.d. to prevent EBV recurrence. The graft remained clear at 5 months post-op, and the patient's BCVA improved to 6/7.5. His endothelial count was 1830, which was ∼ 79% of the original value. Inserting a self-made cushion can enable donor corneas with narrow scleral rims to be used in DSAEK procedures and avoids unwanted switching from endothelial keratoplasty to penetrating keratoplasty (PKP).
منابع مشابه
Donor and surgical risk factors for primary graft failure following Descemet’s stripping automated endothelial keratoplasty in Asian eyes
BACKGROUND Descemet's stripping automated endothelial keratoplasty (DSAEK) has been shown to have superior refractive and visual results compared with penetrating keratoplasty, but higher rates of primary graft failure (PGF). This paper presents donor and surgical risk factors for PGF in DSAEK cases in Asian eyes. DESIGN Retrospective case-control study. PARTICIPANTS All consecutive patient...
متن کاملChange of recipient corneal endothelial cells after non-descemet's stripping automated endothelial keratoplasty in a rabbit model.
PURPOSE We used a rabbit model to evaluate the interface embedded between the recipient corneas and transplanted donor corneal discs after non-Descemet's stripping automated endothelial keratoplasty (nDSAEK). METHODS Unilateral DSAEK and nDSAEK surgeries were performed on New Zealand white rabbits. In vivo confocal microscopy was performed to show: the changes in corneal endothelial cells emb...
متن کاملHistologically proven epithelial ingrowth in failed Descemet stripping automated endothelial keratoplasty (DSAEK) managed by repeat DSAEK
PURPOSE To report a case of corneal graft failure due to epithelial ingrowth after an uneventful combined Descemet stripping automated endothelial keratoplasty (DSAEK) and phacoemulsification cataract surgery with intraocular lens implant treated successfully with a repeat DSAEK. METHODS A 77-year-old male patient underwent combined DSAEK and phacoemulsification with intraocular lens implant ...
متن کاملNo-Touch Technique and a New Donor Adjuster for Descemet's Stripping Automated Endothelial Keratoplasty
PURPOSE One difficulty with Descemet's stripping automated endothelial keratoplasty (DSAEK) is air management during surgery and donor endothelial lamella centering. We evaluated the no-touch technique for donor centering and the use of a newly developed DSAEK donor adjuster. METHODS We evaluated the records of 12 consecutive patients (mean age 75.3 years) with bullous keratopathy who had und...
متن کاملCorneal Donor Tissue Preparation for Endothelial Keratoplasty
Over the past ten years, corneal transplantation surgical techniques have undergone revolutionary changes. Since its inception, traditional full thickness corneal transplantation has been the treatment to restore sight in those limited by corneal disease. Some disadvantages to this approach include a high degree of post-operative astigmatism, lack of predictable refractive outcome, and disturba...
متن کامل