Synchronization of ventricular fibrillation with real-time feedback pacing: implication to low-energy defibrillation.
نویسندگان
چکیده
Wavefront synchronization is an important aspect preceding the termination of ventricular fibrillation (VF). We evaluated the defibrillation efficacy of a novel multisite pacing algorithm using optical recording-guided synchronized pacing (SyncP) in the excitable gaps. We compared the effects of SyncP with traditional overdrive pacing (ODP) at 90% of the VF cycle length (VFCL) and high-frequency pacing (HFP; 43-215 Hz) on spontaneous VF termination in isolated rabbit hearts. For SyncP, the pacing current was triggered by the activation of a reference site and was delivered when the optical potential of the pacing site was in an excitable gap. We measured VFCL and the spatial dispersion of VFCL (SDCL) from five points (3 points in the paced area and 2 points in the nonpaced area) and the distribution of phase singularities during the prepacing, pacing, and postpacing periods. The results showed that 1) the VF termination rate of SyncP (16.0%, n = 106) was higher than that of ODP (2.1%, n = 48, P < 0.01) or HFP (1.6%, n = 129, P < 0.0001); 2) energy consumption for SyncP (7.6 +/- 9.3 mJ) was significantly lower than that of ODP (14.0 +/- 14.8 mJ, P < 0.0001); and 3) SyncP, but not ODP or HFP, decreased SDCL in the paced area during the pacing (P < 0.01) and postpacing (P < 0.05) periods compared with the prepacing period. We conclude that SyncP is effective in inducing wavefront synchronization and is more effective at facilitating spontaneous VF termination than non-SyncP.
منابع مشابه
Intraoperative defibrillation threshold testing and postoperative long-term efficacy of cardioverter-defibrillator implantation
The aim of this study was to determine the defibrillation threshold (DFT) of implantable cardioverter-defibrillators (ICDs) and outcomes of treatment. Sixty-four patients received cardioverter-defibrillator implantation. During implantation, the DFT was determined by the defibrillation safety margin (DSM). All patients were followed up for 12-48 months after the implantation. The overall DFT wa...
متن کاملInternal cardioversion of atrial fibrillation in sheep.
BACKGROUND The cardioversion efficacy of multiple defibrillation waveforms and electrode systems was compared in a sheep model of atrial fibrillation. METHODS AND RESULTS Sustained atrial fibrillation could be induced with rapid atrial pacing in 23 (55%) of the animals. This study was performed in four parts. Six sheep with sustained atrial fibrillation were used for data analysis for each pa...
متن کاملLow energy defibrillation in human cardiac tissue: a simulation study.
We aim to assess the effectiveness of feedback-controlled resonant drift pacing as a method for low energy defibrillation. Antitachycardia pacing is the only low energy defibrillation approach to have gained clinical significance, but it is still suboptimal. Low energy defibrillation would avoid adverse side effects associated with high voltage shocks and allow the application of implantable ca...
متن کاملA prospective evaluation of two defibrillation safety margin techniques in patients with low defibrillation energy requirements.
INTRODUCTION In patients undergoing defibrillator implantation, an appropriate defibrillation safety margin has been considered to be either 10 J or an energy equal to the defibrillation energy requirement. However, a previous clinical report suggested that a larger safety margin may be required in patients with a low defibrillation energy requirement. Therefore, the purpose of this prospective...
متن کاملLow-energy multistage atrial defibrillation therapy terminates atrial fibrillation with less energy than a single shock.
BACKGROUND Implantable device therapy of atrial fibrillation (AF) is limited by pain from high-energy shocks. We developed a low-energy multistage defibrillation therapy and tested it in a canine model of AF. METHODS AND RESULTS AF was induced by burst pacing during vagus nerve stimulation. Our novel defibrillation therapy consisted of 3 stages: stage (ST) 1 (1-4 low-energy biphasic [BP] shoc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 285 6 شماره
صفحات -
تاریخ انتشار 2003