Inter-observer agreement, diagnostic sensitivity and specificity of animal-based indicators of young lamb welfare.

نویسندگان

  • C J Phythian
  • N Toft
  • P J Cripps
  • E Michalopoulou
  • A C Winter
  • P H Jones
  • D Grove-White
  • J S Duncan
چکیده

A scientific literature review and consensus of expert opinion used the welfare definitions provided by the Farm Animal Welfare Council (FAWC) Five Freedoms as the framework for selecting a set of animal-based indicators that were sensitive to the current on-farm welfare issues of young lambs (aged ≤ 6 weeks). Ten animal-based indicators assessed by observation - demeanour, response to stimulation, shivering, standing ability, posture, abdominal fill, body condition, lameness, eye condition and salivation were tested as part of the objective of developing valid, reliable and feasible animal-based measures of lamb welfare The indicators were independently tested on 966 young lambs from 17 sheep flocks across Northwest England and Wales during December 2008 to April 2009 by four trained observers. Inter-observer reliability was assessed using Fleiss's kappa (κ), and the pair-wise agreement with an experienced, observer designated as the 'test standard observer' (TSO) was examined using Cohen's κ. Latent class analysis (LCA) estimated the sensitivity (Se) and specificity (Sp) of each observer without assuming a gold standard and predicted the Se and Sp of randomly selected observers who may apply the indicators in the future. Overall, good levels of inter-observer reliability, and high levels of Sp were identified for demeanour (κ = 0.54, Se ≥ 0.70, Sp ≥ 0.98), stimulation (κ = 0.57, Se = 0.30 to 0.77, Sp ≥ 0.98), shivering (κ = 0.55, Se = 0.37 to 0.85, Sp ≥ 0.99), standing ability (0.54, Se ≥ 0.80, Sp ≥ 0.99), posture (κ = 0.45, Se ≥ 0.56, Sp = 0.99), abdominal fill (κ = 0.44, Se = 0.39 to 0.98, Sp = 0.99), body condition (κ = 0.72, Se ⩾ 0.38 to 0.90, Sp = 0.99), lameness (κ = 0.68, Se > 0.73, Sp = 1.00), and eye condition (κ = 0.72, Se ≥ 0.86, Sp = 0.99). LCA predicted that randomly selected observers had Se > 0.77 (acceptable), and Sp ≥ 0.98 (high) for assessments of demeanour, lameness, abdominal fill posture, body condition and eye condition. The diagnostic performance of some indicators was influenced by the composition of the study population, and it would be useful to test the indicators on lambs with a greater level of outcomes associated with poor welfare. The findings presented in this paper could be applied in the selection of valid, reliable and feasible indicators used for the purposes of on-farm assessments of lamb welfare.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Intra-Canal Posts on Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography in Detection of Vertical Root Fractures

Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics. Cone Beam Computed Tomography (CBCT)  has significantly enhanced image quality compared to digital radiography (DR) and greatly aids the diagnosis of VRFs but, metal artifacts has remained as a problem in VRF detection.  This study evaluated the effect of intra canal posts on the diagnostic accuracy of CBCT and D...

متن کامل

Comparison of the Diagnostic Accuracy of Digital Intraoral Radiography with PSP and CBCT in the Detection of Horizontal and Vertical Dental Root Fractures

Background and Aim: Clinical and radiographic diagnoses of dental root fractures have always been difficult and require high accuracy in dental care and treatment. The aim of this study was to compare the diagnostic accuracy of intraoral digital radiography (PSP) and CBCT in the detection of horizontal and vertical root fractures (HRF and VRF). Materials and Methods: For this experimental stud...

متن کامل

Cone-beam computed tomography performance and endodontic filling material influence in the diagnosis of horizontal root fracture

Introduction: The aim of this study was to investigate the accuracy of Cone-beam computed tomography(CBCT) in detecting the horizontal root fractures (HRFs) in teeth with and without gutta-percha. Materials & Methods: This in vitro study was performed on 100 mandibular and maxillary single-rooted teeth. In 55 samples, the canals were prepared. Then, the horizontal fracture was induced randomly...

متن کامل

Comparison of Accuracy and Observer Agreement in the Detection of Simulated External Root Resorption Using Conventional Digital Radiography and Digitally Filtered Radiography

Introduction: External root resorption is a clinical problem that often cannot be detected clinically. Thus, radiography plays a crucial role in its diagnosis. However, optimal radiographic quality with minimal radiation exposure {2.1 [EN] Verify English word/phrase choice} is an important factor in selecting the appropriate radiographic technique. The aim of this study was the comparison of ac...

متن کامل

مقایسه دقت فیلمهای Primax و Insight و تصاویر دیجیتالی CMOS-APS در تشخیص پوسیدگی‌های جانبی دندانهای خلفی به صورت آزمایشگاهی

Introduction: Radiography is one of the most important diagnostic methods for evaluation of dental caries. On the other hand, the least amount of radiation along with high quality is a main gold standard. The purpose of this study was to compare the diagnostic accuracy of Primax, Insight Radiographic films, and direct digital images (Schick CMOS-APS), in detection of interproximal natural Carie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Animal : an international journal of animal bioscience

دوره 7 7  شماره 

صفحات  -

تاریخ انتشار 2013