Comparative Planning of Flattening-Filter-Free and Flat Beam IMRT for Hypopharynx Cancer as a Function of Beam and Segment Number

نویسندگان

  • Yvonne Dzierma
  • Frank G. Nuesken
  • Jochen Fleckenstein
  • Patrick Melchior
  • Norbert P. Licht
  • Christian Rübe
چکیده

Although highly conformal dose distributions can be achieved by IMRT planning, this often requires a large number of segments or beams, resulting in increased treatment times. While flattening-filter-free beams offer a higher dose rate, even more segments may be required to create homogeneous target coverage. Therefore, it is worthwhile to systematically investigate the dependence of plan quality on gantry angles and number of segments for flat vs. FFF beams in IMRT planning. For the practical example of hypopharynx cancer, we present a planning study of flat vs. FFF beams using three different configurations of gantry angles and different segment numbers. The two beams are very similar in physical properties, and are hence well-suited for comparative planning. Starting with a set of plans of equal quality for flat and FFF beams, we assess how far the number of segments can be reduced before the plan quality is markedly compromised, and compare monitor units and treatment times for the resulting plans. As long as a sufficiently large number of segments is permitted, all planning scenarios give good results, independently of gantry angles and flat or FFF beams. For smaller numbers of segments, plan quality decreases both for flat and FFF energies; this effect is stronger for fewer gantry angles and for FFF beams. For low segment numbers, FFF plans are generally worse than the corresponding flat beam plans, but they are less sensitive to a decrease in segment number if many gantry angles are used (18 beams); in this case the quality of flat and FFF plans remains comparable even for few segments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric Comparison between 6MV Flattened Filter and Flattening Filter Free Photon Beams in the Treatment of Glioblastoma with IMRT Technique: A Treatment Planning Study

Introduction: The present study evaluated the dosimetric comparison between 6MV flattened filter (FF) and flattening filter-free (FFF) photon beams in intensity-modulated radiation therapy (IMRT) technique for the treatment of glioblastoma (GBM) patients. Material and Methods: The present study was conducted on 10 patients with GBM previously...

متن کامل

mARC Treatment of Hypopharynx Carcinoma with Flat and Flattening-Filter-Free Beam Energies – A Planning Study

BACKGROUND The recently implemented mARC-rotation-technique is capable to deliver high dose rate bursts. For the case of hypopharynx cancer plans we evaluate whether the mARC can achieve an advantage in treatment time in comparison to IMRT. These plans consider two arcs with flat and flattening filter free (FFF) beam energies. MATERIALS AND METHODS For 8 hypopharynx-cancer patients step-and-s...

متن کامل

Simultaneous integrated boost therapy of carcinoma of the hypopharynx/larynx with and without flattening filter - a treatment planning and dosimetry study

BACKGROUND The aim of this study was to investigate if the flattening filter free (FFF) irradiation mode of a linear accelerator (linac) is advantageous as compared to the flat beam (FF) irradiation mode in intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) for carcinoma of the hypopharynx / larynx. METHODS Four treatment plans were created for each of 10...

متن کامل

Enhancement of the Dose on 12 MV Linac with Free Flattening Filter Mode

Purpose: In the last years, some studies investigated dosimetric benefits of a free flattening filter for the photon mode in the radiotherapy field. This study aims to provide a theoretical study published and analysis of basic dosimetric properties for a Saturne 43 Linac head to implement free flattening filter beams clinically. Material and Methods: Thi...

متن کامل

Study of Dosimetric Properties of Flattening Filter Free Photon Beam Passing through Cadmium Free Compensator Alloy

Background: This study aims to investigate radiation beam geometry of Cyberknife beam and change in dosimetric characteristics of six megavoltage (6MV) flattening filter free (FFF) beam after passing through high density cadmium free compensator alloy.Material and Methods: In this experimental study, changes in FFF beam dosimetric characteristics after passing through compensator alloy wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014