Balloon-assisted guide catheter positioning to overcome extreme cervical carotid tortuosity: technique and case experience

نویسندگان

  • Lissa Peeling
  • David Fiorella
چکیده

BACKGROUND AND SIGNIFICANCE We describe a method by which to efficiently and atraumatically achieve distal positioning of a flexible guiding catheter beyond extreme cervical tortuosity using a hypercompliant temporary occlusion balloon. METHODS A retrospective review of a prospective neuroendovascular database was used to identify cases in which a hypercompliant balloon catheter (Hyperform or Hyperglide, ev3/Covidien, Irvine, California, USA; Scepter or Scepter XC, Alisa Viejo, California, USA) was used to achieve distal positioning of a flexible guiding catheter (Navion, ev3/Covidien, Irvine, California, USA; Neuron, Penumbra Inc, Alameda, California, USA). After achieving a stable guiding sheath position within the proximal cervical carotid artery, a hypercompliant balloon catheter was manipulated beyond the tortuous cervical internal carotid segment into the distal carotid artery. The balloon was then inflated to anchor it distally within an intracranial (cavernous or petrous) segment of the internal carotid artery. The guiding catheter was then advanced beyond the tortuous cervical segment, over the balloon catheter, as gentle counter traction was applied to the balloon. RESULTS Balloon-assisted guiding catheter placement was used to perform endovascular treatments of 12 anterior circulation aneurysms. One patient underwent coiling alone. Five patients underwent balloon-assisted coiling. One patient underwent balloon and stent assisted coil embolization. Four patients with five carotid aneurysms (one with bilateral carotid aneurysms) underwent vascular reconstruction with the pipeline embolization device. All patients had severe tortuosity of the extracranial carotid system. Three patients had findings consistent with cervical carotid fibromuscular dysplasia. The technique was successful each time it was attempted. No parent artery dissections or catheter induced vasospam were noted in any case. DISCUSSION Hypercompliant balloon catheters can be reliably used to facilitate safe and rapid distal positioning of flexible guiding catheters beyond severe cervical tortuosity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The eJournal of the European Society of Minimally Invasive Neurological Therapy

INTRODUCTION: Direct percutaneous carotid artery puncture (DPCAP) enables endovascular treatment of cerebral aneurysms that are otherwise untreatable in patients with non-navigable proximal vessel tortuosity. Traditionally, microcatheters were advanced directly through the carotid sheath to the intracranial target. This method is insufficient for complex modern neurointerventions necessitating ...

متن کامل

Initial Experience and Feasibility of the New Low-Profile Stingray Catheter as Part of the Antegrade Dissection and Re-Entry Revascularization Strategy for Coronary Chronic Total Occlusions

BACKGROUND During antegrade dissection re-entry (ADR) of chronic total occlusions (CTO), the first-generation Stingray catheter requires the use of large-bore guides (sheathless 7.5 Fr or 8 Fr), which increases the risk for access site-related complications and compromises radial approaches. Smaller guiding sizes necessitate long guidewires (e.g., 300 cm) or guidewire extensions for catheter ad...

متن کامل

GuideLiner Balloon Assisted Tracking (GBAT): A New Addition to the Interventional Toolbox

The use of guide extension catheters, such as GuideLiner, allows for increased guide support and facilitates device delivery in tortuous vessels. In cases which the GuideLiner catheter cannot be advanced even with balloon anchoring technique, we inflate a noncompliant balloon protruding from the GuideLiner catheter at nominal pressure and both the GuideLiner and the balloon are advanced over th...

متن کامل

Balloon-assisted Onyx Embolization of an Extensive Mandibular Gingival Arteriovenous Malformation: a case report

This is a rare case of mandibular arteriovenous gingival malformations with episodes of spontaneous bleeding and referred to our department for emergent interventional therapy. Onyx was chose as embolic agent due to its specific physical properties and infuse under balloon-assisted technique for good penetration of embolic particles into the nidus and feeders. We present this case and share the...

متن کامل

Catheterization of tortuous carotid arteries.

Not uncommonly, when cerebral angiography is performed via the femoral route , a long flexible-tip guide wire may be introduced into the appropriate vessel , but because of tortuosity of the carotid artery the catheter does not follow the guide wire. During attempts to maneuver the catheter into the carotid artery, the catheter and guide wire are displaced into the aortic arch . To overcome thi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2014