Intravascular ultrasound after low and high inflation pressure coronary artery stent implantation.

نویسندگان

  • G Görge
  • M Haude
  • J Ge
  • E Voegele
  • T Gerber
  • H J Rupprecht
  • J Meyer
  • R Erbel
چکیده

OBJECTIVES We sought to characterize the differences seen after low or high pressure coronary artery stent deployment as assessed by intravascular ultrasound. BACKGROUND Until 1992, the success of stent deployment was assessed by angiographic criteria only, but in 1993 the procedure was expanded to include postprocedural single-use intravascular ultrasound imaging. Ultrasound criteria for successful stent deployment were 1) symmetry, 2) minimal lumen diameter > 3.0 mm, 3) no echo-free spaces between the stent and the vessel, and 4) no uncovered dissections. METHODS We used mechanical 4.8F or 3.5F 20- or 30-MHz monorail single-use intravascular ultrasound catheters. RESULTS Fifty-two patients were included, 28 treated in 1991 and 1992 (group A) and 24 treated in 1993 or 1994 (group B); 87% of patients underwent elective stent implantation. The number of echocardiographic studies per patient increased from 1 +/- 0.1 (mean +/- SD) in group A to 2.0 +/- 0.85 in group B. Mean maximal balloon size increased from 3.3 +/- 0.33 to 3.73 +/- 0.24 mm and maximal inflation pressure from 6.9 +/- 1.1 to 15.8 +/- 2.4 bar (p < 0.001). The eccentricity index was 0.915 +/- 0.04 in group B versus 0.87 +/- 0.05 in group A. Minimal lumen diameter measured by echocardiography increased from 2.55 +/- 0.41 mm in group A to 3.14 +/- 0.37 mm in group B. The final mean values per cross-sectional area as a percent of calculated balloon area were similar in group A (67.5 +/- 23%) and group B (66.5 +/- 22.9%). No major acute complications occurred in either group; subacute thrombosis developed in two patients, both in group A. CONCLUSIONS Intravascular ultrasound data confirm that high pressure stent deployment leads to increased minimal lumen area. Despite high pressure stent deployment, homogeneous stent geometry and optimal stent expansion were not observed in all patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Stent Expansion by Stent Balloon Multiple Inflation at Nominal Pressure in Resistant Lesions: A New Technique

Introduction: This study aimed to evaluate the effects of four-time inflation of the stent balloon at nominal pressure on optimal stent expansion in resistant lesions. Materials and Methods: This interventional study was conducted on 39 patients with coronary artery lesions, in whom Zotarolimus-eluting stents (N=20), Paclitaxel-eluting stents (N=11) and other stents (N=8) were deployed four tim...

متن کامل

Pathological Perspective of Drug-Eluting Stent Thrombosis

Although very late stent thrombosis (VLST) after drug-eluting stent (DES) implantation remains a major concern, the precise mechanisms have not been clarified. An association between late acquired incomplete stent apposition (ISA) and VLST of DES has been suggested by several intravascular ultrasound studies demonstrating very high prevalence of ISA in the setting of VLST. To clarify the pathol...

متن کامل

Coronary rupture during stent implantation.

A 69-year-old patient with unstable angina presented to cardiac catheterization with a tight lesion in the mid right coronary artery (Figure 1A) and moderate lesions in the left main and left anterior descending coronary arteries. During coronary angioplasty, a stent was electively implanted in the right coronary artery, with good initial results. However, during subsequent aggressive, high-pre...

متن کامل

[Implications of late expansion of self-expanding stents on neointimal response: a serial study with intravascular ultrasound].

INTRODUCTION AND OBJECTIVES A unique property of self-expanding stents is the continuous force exerted against the vessel wall, which may induce additional arterial damage with implications on restenosis. The main purpose of this study is to evaluate the consequences of late self-expansion of coronary Wallstents. METHODS Eleven patients with Wallstents implanted in native coronary arteries, i...

متن کامل

Comparison of quantitative coronary angiography, intravascular ultrasound, and coronary pressure measurement to assess optimum stent deployment.

BACKGROUND Although intravascular ultrasound (IVUS) is the present standard for the evaluation of optimum stent deployment, this technique is expensive and not routinely feasible in most catheterization laboratories. Coronary pressure-derived myocardial fractional flow reserve (FFRmyo) is an easy, cheap, and rapidly obtainable index that is specific for the conductance of the epicardial coronar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 26 3  شماره 

صفحات  -

تاریخ انتشار 1995